RT-SVX34R-EN
143
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e w
w//C
Ca
ap
pa
acciitto
orrss!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err a
an
nd
d d
diisscch
ha
arrg
ge
e
cca
ap
pa
acciitto
orrss b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss a
an
nd
d d
diisscch
ha
arrg
ge
e a
allll m
mo
otto
orr sstta
arrtt//rru
un
n
cca
ap
pa
acciitto
orrss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
nn
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. F
Fo
orr v
va
arriia
ab
blle
e
ffrre
eq
qu
ue
en
nccy
y d
drriiv
ve
ess o
orr o
otth
he
err e
en
ne
errg
gy
y sstto
orriin
ng
g
cco
om
mp
po
on
ne
en
nttss p
prro
ov
viid
de
ed
d b
by
y T
Trra
an
ne
e o
orr o
otth
he
errss,, rre
effe
err tto
o
tth
he
e a
ap
pp
prro
op
prriia
atte
e m
ma
an
nu
uffa
accttu
urre
err’’ss lliitte
erra
attu
urre
e ffo
orr
a
allllo
ow
wa
ab
blle
e w
wa
aiittiin
ng
g p
pe
erriio
od
dss ffo
orr d
diisscch
ha
arrg
ge
e o
off
cca
ap
pa
acciitto
orrss.. V
Ve
erriiffy
y w
wiitth
h a
a C
CA
AT
T IIIIII o
orr IIV
V v
vo
ollttm
me
ette
err
rra
atte
ed
d p
pe
err N
NF
FP
PA
A 7
70
0E
E tth
ha
att a
allll cca
ap
pa
acciitto
orrss h
ha
av
ve
e
d
diisscch
ha
arrg
ge
ed
d..
F
Fo
orr a
ad
dd
diittiio
on
na
all iin
nffo
orrm
ma
attiio
on
n rre
eg
ga
arrd
diin
ng
g tth
he
e ssa
affe
e
d
diisscch
ha
arrg
ge
e o
off cca
ap
pa
acciitto
orrss,, sse
ee
e P
PR
RO
OD
D--S
SV
VB
B0
06
6*
*--E
EN
N..
HIGH VOLTAGE IS PRESENT AT TERMINAL BLOCK
1TB1 OR UNIT DISCONNECT SWITCH 1S14.
2. To modify TR-200 parameters:
a. Press Main Menu button (press [Back] button if
the main menu does not display)
b. Use the [
▲
] and [
▼
] buttons to find the
parameter menu group (first part of parameter
number)
c. Press [OK]
d. Use [
▲
] and [
▼
] buttons to select the correct
parameter sub-group (first digit of second part
of parameter number)
e. Press [OK]
f.
Use [
▲
] and [
▼
] buttons to select the specific
parameter
g. Press [OK]
h. To move to a different digit within a parameter
setting, use the [
►◄
] buttons (Highlighted area
indicates digit selected for change)
i.
Use [
▲
] and [
▼
] buttons to adjust the digit
j.
Press [Cancel] button to disregard change, or
press [OK] to accept change and enter the new
setting
3. Repeat step two for each menu selection setting in
4. To reset TR-200 programming parameters back to
the factory defaults:
a. Go to parameter 14-22 Operation Mode
b. Press [OK]
c. Select “Initialization”
d. Press [OK]
e. Cut off the mains supply and wait until the
display turns off.
f.
Reconnect the mains supply - the frequency
converter is now reset.
g. Ensure parameter 14-22 Operation Mode has
reverted back to “Normal Operation”.
N
No
otte
ess::
•
Steps 4 resets the drive to the default
factory settings. The program
parameters listed in
will need to be verified or changed as
described in item 2.
•
Some of the parameters listed in the
tables are motor specific. Due to
various motors and efficiencies
available, use only the values stamped
on the specific motor nameplate. Do
not use the Unit nameplate values.
•
A backup copy of the current setup
may be saved to the LCP before
changing parameters or resetting the
drive. See LCP Copy in the VFD
Operating Instructions for details.
5. After verifying that the VFD(s) are operating
properly, put the unit into normal operation.
Содержание Voyager Commercial
Страница 153: ...RT SVX34R EN 153 N No ot te es s...
Страница 154: ...154 RT SVX34R EN N No ot te es s...
Страница 155: ...RT SVX34R EN 155 N No ot te es s...