background image

2

BAS-PRC006-EN

The Tracer ZN511 and ZN521 zone 
controllers provide digital control for 
several types of heating, ventilating, and 
air-conditioning (HVAC) equipment.

The Tracer ZN511 controls:

• Water-source heat pumps
• Fan coils
• Cabinet heaters

The Tracer ZN521 controls:

• Unit ventilators
• Fan coils
• Cabinet heaters
• Blower coils

Tracer zone controllers operate as stand-
alone devices or as part of a Trane 
Integrated Comfort system (ICS). The 
controllers communicate with a Tracer 
Summit building automation system via 
a LonTalk communication link. LonTalk 
allows the controllers to operate in peer-
to-peer configuration and to 
communicate with other compatible 
building control systems.

Trane offers a variety of wall-mounted 
zone sensors for Tracer controllers. Zone 
sensors come with any of the following 
options:

• Temperature setpoint thumbwheel
• Fan speed switch

ON

 and 

CANCEL

 occupancy buttons

• A communications jack for the Rover 

service tool

Introduction

© 2005 American Standard Inc.

™ ®

 The following are trademarks or registered trademarks of their respective com-

panies: Windows from Microsoft Corporation; LonTalk and LonMark from Echelon Cor-

poration; Integrated Comfort, Rover, Tracer, and Tracer Summit from Trane.

Содержание Tracer ZN511

Страница 1: ...BAS PRC006 EN January 2005 Tracer Controls Tracer ZN511 and ZN521 Zone Controllers...

Страница 2: ...tem via a LonTalk communication link LonTalk allows the controllers to operate in peer to peer configuration and to communicate with other compatible building control systems Trane offers a variety of...

Страница 3: ...4 Inputs and outputs 4 Features 4 Wiring diagram for the ZN511 zone controller 5 Tracer ZN521 zone controller 6 Inputs and outputs 6 Features 6 Wiring diagram for the ZN521 zone controller 8 Network a...

Страница 4: ...rough the LonTalk communication link can also be used The input allows the controllers to use unoccupied setback temperature setpoints Random start This feature randomly staggers multiple unit start u...

Страница 5: ...GND FAN AI1 LED ZN PIN GND ZONE SENSOR SERVICE ANALOG INPUTS COMM5 COMM5 AC POWER GND GND GND 24V BINARY INPUTS BI3 BI2 BI1 BI4 V4 BINARY OUTPUTS 3 BI5 V5 2 1 4 5 6 LED STATUS 5 4 3 2 1 On Cancel 6 H...

Страница 6: ...s to provide accurate two pipe system changeover for 1heat 1 cool applications Automatic heat cool mode determination The Tracer ZN521 automatically determines whether heating or cooling is needed to...

Страница 7: ...tive humidity input An analog input can be configured as a relative humidity input The controller can use this value to support the dehumidification function Active dehumidification This feature keeps...

Страница 8: ...AI3 FAN GND AI1 ZN GND LED SET PIN ZONE SENSOR SERVICE ANALOG INPUTS COMM5 COMM5 AC POWER 24V 24V GND 24V BINARY INPUTS BI3 BI1 BI2 BI4 BINARY OUTPUTS 2 1 4 3 7 6 5 8 9 LED STATUS 10 5 4 3 2 1 On Canc...

Страница 9: ...cation on the LonTalk communication link Figure 3 Tracer zone controllers network architecture Building control unit BCU Tracer Summit PC workstation Unit ventilator Water source heat pump Zone sensor...

Страница 10: ...sor options Figure 4 Zone sensors compatible with Tracer zone controllers BAS order number Use Fan Zone Timed override buttons Comm jack High Med Low Auto Off Setpoint thumbwheel Temperature sensor On...

Страница 11: ...C Relative humidity From 5 to 95 noncondensing Agency listings compliance CE Immunity EN 50082 1 1997 EN 50082 2 1995 CE Emissions EN 50081 1 1992 CISPR 22 UL and C UL listed Energy management system...

Страница 12: ...ght to change design and specifications without notice Literature Order Number BAS PRC006 EN File Number PL ES BAS 000 PRC006 0105 Supersedes February 2002 The Trane Company An American Standard Compa...

Отзывы: