RLC-SVX19G-GB
47
11
UNT-PRC002-GB
Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan
Power level in dB(A), per Hz frequency band
Overall power
Unit
speed
125
250
500
1000
2000
4000
8000
dB(A)
1
55
50
42
37
37
31
30
46
FWD 08
2
57
54
47
40
30
38
40
50
3
58
57
50
42
32
40
43
53
1
57
51
45
42
34
33
28
48
FWD 10
2
58
54
48
45
38
39
35
51
3
60
58
50
48
40
42
39
54
1
57
51
45
42
34
33
28
48
FWD 12
2
58
54
48
45
38
39
35
51
3
60
58
50
48
40
42
39
54
1
56
62
50
48
39
38
36
56
FWD 14
2
61
66
55
53
47
46
45
60
3
63
69
58
56
50
50
49
63
1
57
63
51
49
40
39
37
57
FWD 20
2
61
66
55
53
47
46
45
60
3
63
69
58
56
50
50
49
63
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan
Power level in dB(A), per Hz frequency band
Overall power
Unit
speed
125
250
500
1000
2000
4000
8000
dB(A)
1
56
55
55
53
46
45
42
57
FWD 08
2
63
62
60
60
53
53
53
64
3
66
65
63
62
56
55
57
67
1
62
58
55
58
51
48
44
61
FWD 10
2
66
63
60
62
56
55
52
66
3
70
67
63
65
59
59
57
69
1
62
58
55
58
51
48
44
61
FWD 12
2
66
63
60
62
56
55
52
66
3
70
67
63
65
59
59
57
69
1
66
65
65
65
57
50
46
68
FWD 14
2
73
72
69
71
64
59
57
74
3
78
76
73
75
69
64
63
78
1
68
72
64
64
56
52
50
69
FWD 20
2
76
76
68
71
65
61
61
75
3
78
79
71
74
69
66
66
78
Table 11b – General data RTAF 090 225 High Seasonal Efficiency Short - Standard and Low noise - R1234ze
RTAF
RTAF
RTAF
RTAF
RTAF
RTAF
RTAF
RTAF
RTAF
RTAF
090
100
110
120
130
145
155
185
200
225
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
HSS SN
LN
Cooling Capacity (1)
(kW)
320
349
386
416
448
502
543
608
722
839
Unit electrical data (2) (3) (4)
Maximum Power input in cooling
(kW)
166
180
194
218
241
266
288
292
335
382
Unit amps (4) (5)
Unit rated amps (Max comfan+control)
(A)
253
275
296
332
368
406
439
445
510
581
Unit start up amps starting Amps of the
larges compr+RLA of 2nd compr+RLA of all
fans+control)
(A)
253
275
296
332
368
406
439
445
510
581
Displacement Power Factor (DPF)
mm²
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
Max power cable cross section
Power factor
(kA)
1*240
1*240
1*240
1*240
1*240
2*300
2*300
2*300
2*300
2*300
Disconnect switch size
(A)
400
400
500
500
500
630
630
630
800
800
Compressor
Quantity
#
2
2
2
2
2
2
2
2
2
2
Type
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Model (8)
45/45
55/45
55/55
65/55
65/65
78/65
78/78
78/78
78/78
78/78
Max Compr Power input Circuit 1 / Circuit 2
kW
74/74
89/74
89/89
112/89
112/112 134/112 134/134 134/134 155/155 179/179
Max Amps Circuit1 / Circuit 2 (3) (4)
(A)
45/45
55/45
55/55
65/55
65/65
78/65
78/78
78/78
78/78
78/78
Start up Amps Circuit1 / Circuit 2 (3)(4)
(A)
113/113 135/113 135/135 171/135 171/171 203/171 203/203 203/203 236/236 271/271
Motor RPM
(rpm)
3000
3000
3000
3000
3000
3000
3000
3000
3600
4200
Oil sump heater Circuit1 / Circuit 2
(W)
0.550
0.550
0.550
0.550
0.550
0.550
0.550
0.550
0.550
0.550
Evaporator
Quantity
#
1
1
1
1
1
1
1
1
1
1
Type
Flooded shell and tube heat exchanger
Evaporator model
115B
115A
115A
165C
165B
200C
200C
200B
250B
250B
Evaporator Water Content volume
(l)
51
58
58
64
74
89
89
99
118
118
Antifreeze Heater
(W)
1640
1640
1640
1640
1640
1640
1640
2040
2040
2040
Evap. Water Flow rate - Minimum (6)
Evap. Water Flow rate - Maximum
(l/s)
8.0
9.4
9.4
11.1
11.6
13.0
13.0
14.2
17.9
17.9
Evap. Water Flow rate - Maximum
(l/s)
29.6
34.7
34.7
41.2
43.1
48.0
48.0
52.6
66.5
66.5
Nominal water connection size (Grooved
coupling)
(in) - (mm)
4" - 100 4" - 100 4" - 100 5" - 125 5" - 125 6" - 150 6" - 150 6" - 150 6" - 150 6" - 150
Evap. Water Flow rate - Minimum (6)
Evap. Water Flow rate - Minimum
(l/s)
6.6
7.8
7.8
9.3
9.7
10.8
10.8
11.8
14.9
14.9
Evap. Water Flow rate - Maximum
(l/s)
26.6
31.2
31.2
37.0
38.7
43.1
43.1
47.2
59.7
59.7
Nominal water connection size (Grooved
coupling)
(in) - (mm)
4" - 100 4" - 100 4" - 100 5" - 125 5" - 125 6" - 150 6" - 150 6" - 150 6" - 150 6" - 150
Hydraulic Module Components
Standard head pressure pump option (twin pumps)
Standard head pressure pump option
Available Head Pressure (1)
(kPa)
129
126
111
107
136
121
160
151
131
89
Max Amps
(kW)
5.5
5.5
5.5
5.5
7.5
7.5
11.0
11.0
11.0
11.0
High head pressure pump option (twin pumps)
(A)
11.0
11.0
11.0
11.0
14.4
14.4
20.8
20.8
20.8
20.8
High head pressure pump option
Available Head Pressure (1)
(kPa)
246
243
227
222
212
237
226
218
244
197
Max Amps
(kW)
11.0
11.0
11.0
11.0
11.0
15.0
15.0
15.0
18.5
18.5
Max. Rated Amps
(A)
20.8
20.8
20.8
20.8
20.8
28.0
28.0
28.0
34.5
34.5
Expansion Tank Volume
(l)
80
80
80
80
80
80
80
80
80
80
Max User water loop Volume for factory mounted
expansion tank (1)
(l)
6000
6000
6000
6000
6000
6000
6000
6000
6000
6000
Max. Water-side Operating Pressure without
pump package
(kPa)
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Max. Water-side Operating Pressure with pump
package
(kPa)
450
450
450
450
450
450
450
450
450
450
Antifreeze Heater with pump package
(W)
2360
2360
2360
2360
2360
2360
2360
2760
2760
2760
Condenser
Type
Full aluminum Micro channel heat exchanger
Quantity
#
4/4
4/4
4/4
4/4
4/4
5/5
5/5
6/6
6/6
6/6
Face area per coil
(m²)
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
Condenser Fan (nominal conditions)
Quantity
#
4/4
4/4
4/4
4/4
4/4
5/5
5/5
6/6
6/6
6/6
Diameter
(mm)
800
800
800
800
800
800
800
800
800
800
General Data