Electrical
Data
Table ED-1 — 20-130 Tons Electrical Service Sizing Data
1
— Compressor
Compressor
Nominal Voltage
Number
Standard
High
200
230
460
575
Nominal
Per
Capacity
Capacity
RLA
1
LRA
RLA
1
LRA
RLA
1
LRA
RLA
1
LRA
Tons
Coil Type
Unit
KW (ea)
KW (ea)
(ea)
(ea)
(ea)
(ea)
(ea)
(ea)
(ea)
(ea)
Compressor
20
Std and Hi-Cap
2
9.8
10.2
41.9
269
41.9
251
18.2
117
14.6
94
25
Std and Hi-Cap
1
15.0
15.5
62.8
409
62.8
376
27.3
178
21.8
143
1
9.6
9.9
41.9
269
41.9
251
18.2
117
14.6
94
30
Std and Hi-Cap
2
15.7
15.7
62.8
409
62.8
376
27.3
178
21.8
143
40
Std and Hi-Cap
4
9.8
10.1
41.9
269
41.9
251
18.2
117
14.6
94
50
Std and Hi-Cap
2
15.3
15.4
62.8
409
62.8
376
27.3
178
21.8
143
2
9.8
9.9
41.9
269
41.9
251
18.2
117
14.6
94
55
Std and Hi-Cap
4
15.3
15.6
62.8
409
62.8
376
27.3
178
21.8
143
60
Std and Hi-Cap
4
14.4
15.0
62.8
409
62.8
376
27.3
178
21.8
143
70
Std
2
15.6
—
62.8
409
62.8
376
27.3
178
21.8
143
4
9.9
—
41.9
269
41.9
251
18.2
117
14.6
94
75
Std
2
15.8
—
62.8
409
62.8
376
27.3
178
21.8
143
4
10.1
—
41.9
269
41.9
251
18.2
117
14.6
94
75
Hi-Cap
2
—
16.9
62.8
409
62.8
376
27.3
178
21.8
143
4
—
11.2
41.9
269
41.9
251
18.2
117
14.6
94
90
Std and Hi-Cap
4
15.7
16.3
62.8
409
62.8
376
27.3
178
21.8
143
2
10.5
10.9
41.9
269
41.9
251
18.2
117
14.6
94
105
Std and Hi-Cap
6
15.6
15.9
62.8
409
62.8
376
27.3
178
21.8
143
115
Std
4
16.4
—
62.8
409
62.8
376
27.3
178
21.8
143
4
10.9
—
41.9
269
41.9
251
18.2
117
14.6
94
130
Std
8
15.5
—
—
—
—
—
27.3
178
21.8
143
Note:
1. Use this table only for sizing electrical service. DO NOT USE FOR CALCULATING EER.