Unit dimension

Standard model

Motor

6

A
B
C

883

1153

983

C

1. Only main unit, no accessories selected by the customer: MW(C)D509~524MM***

1433

518

270

487

192

226

237

MW(C)D524MM

14

Detail   A

1243 1270

MW(C)D509MM
MW(C)D512MM
MW(C)D518MM

Dimensions 

(unit: mm)

Model

A

963

793

693

B

720
820
990

152

223

10

14

Air outlet

31

Electrical control box

Drain pipe 
outlet joint 

(3/4" external thread)

23

3/8"

5/8"

29

Draian pan

Unit weight 

18.5

20
23

(Kg)

3/8"

Inlet

pipe Ø

Outlet 
pipe Ø

Dimensions 

(unit: mm)

Model

Inlet

pipe Ø

Outlet 
pipe Ø

1/4"
1/4"

3/8"
1/2"
5/8"

Hoisting hole (4), see detail A

Heat exchanger

Drain pan

Heat exchanger

Electric heater 

(optional)

12

43

21

1

Centrifugal fan

121

H

Remove hot water coil

A

B

6

C

D

2. Main unit + rear air return bottom air return hot water coil + electric heater: MW(C)D509~524MM***

Water outlet pipe joint: 
ZG1/2" for single-row, ZG3/4" for double-row

Bottom return air = 543

Rear return air = 522

270

198

Bottom return air 

(optional)

Rear return air 

(optional)

14

Bottom return air = 248 

Rear return air = 226

198

Rear return air = 243

Bottom return air = 248

1433

1270

1243

Detail   A

720

990

820

963

793

693

A

883

1153

983

B

C

14

Hot 

water coil

29

76

156

186

Hot water coil 

(optional)

11

98

25

3

61

Drainage pipe

Water inlet pipe joint 
ZG1/2" for single-row
ZG3/4" for double-row

223

710x198

Hx198

980x198

810x198

Electrical control box

Drain pipe outlet 

joint (3/4" external thread)

1260x198

5/8"

3/8"

1332

1/4"

3/8"

1/4"

1052

882

782

D

5/8"

1/2"

3/8"

Hoisting hole (6), see detail A

21

1

188

12

Air return plenum

MW(C)D524MM

MW(C)D509MM
MW(C)D512MM
MW(C)D518MM

Ø11

Ø18

Ø11

Ø18

Size of return 

air opening

AMS-SVX04A-EN 

7

Содержание MWC507

Страница 1: ...Indoor Unit Installation Operation Manual Advanced Multi split System Concealed Indoor Unit MW C D507 524 R410A 200061230200 April 2012 AMS SVX04A EN...

Страница 2: ...ormal and reliable operation of the air conditioner The installation of this unit must be executed by the specialized staff designated by our company This manual may not cover any circumstance encount...

Страница 3: ...detection and heat insulation of refrigerant pipe 16 Precautions 17 Connection of drainage pipe 17 Concentrated drainage 18 Drainage testing 18 Electrical control wiring 19 Concealed type indoor unit...

Страница 4: ...d it must accord with Engineering speci cation for electrical equipments and Speci cation for indoor electrical wiring The unit must be earthed properly Be sure to connect the earth wire to the ground...

Страница 5: ...avoid improper connection During operation of the unit never extend the nger stick or rod into the air inlet or outlet In the process of operation or at the just end of operation never touch the refr...

Страница 6: ...air return plenum without strainer without hot water coil A With rear air return plenum with strainer without hot water coil B With rear air return plenum with strainer with single row hot water coil...

Страница 7: ...t rear air return plenum bottom air return plenum hot water coil electric heater MW C D509 524MM Water outlet pipe joint ZG1 2 for single row ZG3 4 for double row Bottom return air 543 Rear return air...

Страница 8: ...3 5 409 295 487 510 113 23 1 Only main unit no accessories selected by the customer MW C D507 518NM 6 B C A 183 5 200 10 126 270 14 Outlet pipe Inlet pipe 14 A 29 Electric heater 12 211 43 207 Electri...

Страница 9: ...t least 4 ones should be used Ensure good ventilation so that the air ow can be blown throughout the room Obstruct should be put away from the air inlet or outlet so that the air may be circulated fre...

Страница 10: ...lowing gure 2 Mounting roof Supply air Wide expansion bolt Wide lock washer Hanging screw Nut B B A A B rivet Supply air channel Supply air channel Supply air channel Air outlet grille Unit roof plate...

Страница 11: ...and x it rmly Check whether the suspension rod is aligned with the unit and lift the unit on the suspension rod Set the drainage slope according to the right gure Make sure that there is a gradient i...

Страница 12: ...ter The return air duct and air outlet duct should be xed to the precast slab of the oor with iron stands and all joints of the air duct should be sealed with sealant The distance between the wall and...

Страница 13: ...e indoor unit after adding a transition duct and another end may be separate or be connected to the air outlet grille as shown in following gure Fan speed of each grille shall be uniform basically so...

Страница 14: ...pe size is too large a metal cut saw may be used but prevent saw dust entering into the pipe Only the are nut attached to the unit may be used Before aring rst mount the nut on the copper tube Check w...

Страница 15: ...en cylinder Pressure hose Pipe size 20 mm below 20 45 mm 45 mm above Max interval m 1 0 1 5 2 0 Purging of refrigerant pipe During erecting and constructing the tting pipe it is hard to avoid dust wat...

Страница 16: ...here is change of pressure check whether each interface welding or ared and the whole system have good tightness and see if there have leakage sources Caution when the air temperature at the time of p...

Страница 17: ...e suspension rods of the horizontal drainage pipe Material Nominal diameter Distance Hard PVC pipe 25 40 mm Less than 1 5 m Connection of drainage pipe Without drainage pump Never install the drainage...

Страница 18: ...rainage pipe Suspension Main air vent Concentrated drainage pipe gradient 1 100 1 1 5m Indoor unit Indoor unit Indoor unit Ceiling 500 Main drainage Drainage testing Check the smoothness of drain afte...

Страница 19: ...the side of the control box and connect to CN3 terminal of the controller After nishing the above wiring close the junction box lid 4 Precautions All wiring should comply with the local laws and regul...

Страница 20: ...5 S6 S7 S8 DIP for model of the indoor unit If model of the indoor unit differs the DIP setting of the control panel is different There are 8 DIP switches on the control panel of the indoor unit of wh...

Страница 21: ...n in following table S5 S6 S7 Address of indoor unit 0 0 0 0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 7 Shift selection for fan speed of the indoor unit There are 8 DIP switches on the co...

Страница 22: ...2 5 MW C D512 0 27 6 4 0 34 1 5 6 74 2 5 MW C D518 0 41 8 2 0 51 1 5 8 71 2 5 MW C D524 0 57 12 7 0 71 1 5 13 41 2 5 Slim model Model Frequency Hz Rated voltage V Range of voltage V Rated current of f...

Страница 23: ...nit 24 hours ahead before startup or the compressor may be damaged ON OFF Mode selection Sleep setting Auxiliary heating function button Fan speed setting PRI setting Time Inquiry set Buttons Quick co...

Страница 24: ...mode of this function is valid after being canceled reset the temperature and fan speed in sleep state 8 Selection of operating mode button Press this button to select the operating mode 9 Reset Pres...

Страница 25: ...pacity of indoor unit kW 03 Indoor unit coil inlet temperature T2 04 Indoor unit coil midpoint temperature T3 05 Indoor unit coil outlet temperature T4 06 Indoor return air temperature T1 07 Opening o...

Страница 26: ...utral Power line Coil middle temperature sensor Coil outlet temperature sensor Coil inlet temperature sensor Connector on main board Ground Room temperature sensor Factury wiring EH Electric heater 4...

Страница 27: ...2 3 N2 N1 CN1 CN2 CN8 3 YE YE Out door UNIT In door UNIT Fan motor FAN EV1 TB1 WRC J1 F1 T Relay for electric heater Wiring control panel Terminal connector Fuse Transformer Electronic expansion valve...

Страница 28: ...p M2 PUMP SA1 CN12 PUMP SA1 Out door UNIT In door UNIT MAIN BOARD MED LOW HIGH SUP LOW AN1 AN2 AN3 AN4 Fan motor Relay for electric heater Wiring control panel Terminal connector Fuse Transformer Elec...

Страница 29: ...D MED LOW HIGH SUP LOW Pump FAN EV1 TB1 WRC J1 F1 T N L EH PUMP SA1 AN1 AN2 AN3 AN4 Fan motor Relay for electric heater Wiring control panel Terminal connector Fuse Transformer Electronic expansion va...

Страница 30: ...tact your local district office Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Literature Order Number...

Отзывы: