UH1-DH1-SF-1L
Service Facts
17
2 Flash Fault LED
Cycle power to
furnace and call
for heat
Does gas
ignite?
YES
NO
Is outlet gas
pressure
~3.5"WC (NG)
~11.0"WC (LP)
YES
Do all burners
ignite within 5
seconds?
Check igniter
position and
correct if needed.
Check operation
Adjust manifold gas
pressure
to ~3.5"WC (NG)
~11.0"WC (LP)
Check operation
NO
Clean and align
burners correctly.
Check operation
NO
YES
Measure flame
current. Is flame
current less than 1
micro-amp?
(3-4 ua = Normal)
YES
Is flame sensor
located
correctly?
Replace flame
sensor. Check
operation
YES
Correct and check
operation
NO
Flame sensor is
good
NO
Is minimum
outlet gas
manifold
pressure
maintained?
Does inlet gas
pressure drop
more than 2"
WC
NO
Correct inlet gas
pressure
Check operation
Replace Gas Valve
Check operation
YES
Disconnect electrical
power to furnace.
Connect manometer
to oulet gas pressure
connector
NO
Cycle power to
furnace and call
for heat
YES
DEFINITION
RETRY Lock Out = 3 unsuccessful tries for
ignition within a single call for heat
Flame has never been sensed
RECYCLE Lock Out = 10 recycles within a
single call for heat.
Flame is sensed & then lost
For CORRECT
positioning of the
igniter and flame
sensor, see figure
on next page
Disconnect electrical
power to furnace.
Connect manometer
to inlet gas pressure
connector
Is inlet gas pressure
above 14" WC or less than
nameplate minimum ?
NO
Correct inlet gas
pressure
Check operation
YES
Downflow model
*DH1D110A960 only:
Outlet gas pressure
~4.5"WC (NG)
~11"WC (LP)
Downflow model
*DH1B065A942 only:
Outlet gas pressure
~3.0"WC (NG)
~9.5"WC (LP)
Downflow model
*DH1D110A960 only:
Adjust manifold gas pressure
to ~4.5"WC (NG)
~11"WC (LP)
Downflow model
*DH1B065A942 only:
Outlet gas pressure
~3.0"WC (NG)
~9.5"WC (LP)
Check operation
NO
Содержание DH1B040A9241C Series
Страница 6: ...6 UH1 DH1 SF 1L Service Facts continued on next page WIRING DIAGRAM From Dwg D345803P01 Rev A...
Страница 7: ...UH1 DH1 SF 1L Service Facts 7 SCHEMATIC DIAGRAM From Dwg D345803P01 Rev A...
Страница 8: ...8 UH1 DH1 SF 1L Service Facts continued on next page WIRING DIAGRAM From Dwg D345804P01 Rev A...
Страница 9: ...UH1 DH1 SF 1L Service Facts 9 SCHEMATIC DIAGRAM From D345804P01 Rev A...
Страница 18: ...18 UH1 DH1 SF 1L Service Facts...