Installer’s Guide
IFC ERROR FLASH CODES
Literature Order Number 18-CD31D1-5
File Number
18-CD31D1-5
Supersedes 18-DC31D1-4
Date 06/11
See Service Facts for additional troubleshooting
information.
GREEN LED
AMBER LED RED LED
ERROR
FLASH
FLASH
FLASH
1
Flame Sensed when no flame should be present
2
Pressure switch stuck closed
3
1st stage pressure switch is open / not closing
4
Open thermal limit or open rollout
5
Open low voltage fuse
6
1st stage pressure switch opened 5 times within one cycle--1 hour lockout
7
System lockout Retry
8
System lockout Recycle
9
Reverse polarity or poor grounding
10
Gas valve energized without call for heat
12
Ignitor relay failure internal in board. Replace IFC
Solid
Gas valve relay failure internal in board. Replace IFC
3 Double
2nd stage pressure switch open; system reverts back to 1st stage heat
1
1st stage call for heat
2
2nd stage call for heat
3
W2 call present without W1
4
Y call present without G
Rapid
Low flame sense current
1
Standby mode or call for cooling
* The diagnostics will indicate the specific fault through the following code: