110
WSHP-SVX01Y-EN
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss C
Ch
he
em
miicca
allss!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w tth
hiiss ssa
affe
etty
y p
prre
ecca
au
uttiio
on
n cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y.. C
Co
oiill cclle
ea
an
niin
ng
g
a
ag
ge
en
nttss cca
an
n b
be
e e
eiitth
he
err a
acciid
diicc o
orr h
hiig
gh
hlly
y a
allkka
alliin
ne
e a
an
nd
d
cca
an
n b
bu
urrn
n sse
ev
ve
erre
elly
y iiff cco
on
ntta
acctt w
wiitth
h sskkiin
n o
orr e
ey
ye
ess
o
occccu
urrss..
H
Ha
an
nd
dlle
e cch
he
em
miicca
all cca
arre
effu
ulllly
y a
an
nd
d a
av
vo
oiid
d cco
on
ntta
acctt w
wiitth
h
sskkiin
n.. A
AL
LW
WA
AY
YS
S w
we
ea
arr P
Pe
errsso
on
na
all P
Prro
otte
eccttiiv
ve
e
E
Eq
qu
uiip
pm
me
en
ntt ((P
PP
PE
E)) iin
nccllu
ud
diin
ng
g g
go
og
gg
glle
ess o
orr ffa
acce
e ssh
hiie
elld
d,,
cch
he
em
miicca
all rre
essiisstta
an
ntt g
gllo
ov
ve
ess,, b
bo
oo
ottss,, a
ap
prro
on
n o
orr ssu
uiitt a
ass
rre
eq
qu
uiirre
ed
d.. F
Fo
orr p
pe
errsso
on
na
all ssa
affe
etty
y rre
effe
err tto
o tth
he
e cclle
ea
an
niin
ng
g
a
ag
ge
en
ntt m
ma
an
nu
uffa
accttu
urre
err’’ss M
Ma
atte
erriia
allss S
Sa
affe
etty
y D
Da
atta
a S
Sh
he
ee
ett
a
an
nd
d ffo
ollllo
ow
w a
allll rre
ecco
om
mm
me
en
nd
de
ed
d ssa
affe
e h
ha
an
nd
dlliin
ng
g
p
prra
accttiicce
ess..
It should be noted that the water quality should be
checked periodically (See below).
Table 59.
Water quality
Scaling
Amount
Calcium and magnesium (total
hardness)
Less than 350 ppm
Corrosion
pH
7-9.5
Hydrogen Sulfide
Less than 1 ppm
Table 59.
Water quality (continued)
Scaling
Amount
Sulfates
Less than 25 ppm
Chlorides
Less than 125 ppm
Carbon Dioxide
Less than 75 ppm
Total dissolved solids (TDS)
Less than 1000 ppm
Biological Growth
Iron Bacteria
Low
Erosion
Suspended Solids
Low
Condensate Trap
For units incorporating a negative trap design, ensure
that the condensate system is primed with water at all
times. Allowing a negative, pressure condensate
system to run dry could cause a break in the
condensate seal allowing the fan to draw water from
the condensate line to spray moisture into the
mechanical system. By maintaining a primed
condensate trap, a seal will be created and will help
prevent these complications.
Содержание Axiom GEH-E035
Страница 116: ...116 WSHP SVX01Y EN Figure 83 GEH_V 6 to 25 tons deluxe 24V 460V 60 Hz 3 ph W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 117: ...WSHP SVX01Y EN 117 Figure 84 GEH_V 6 to 25 tons Tracer ZN524 460V 60 Hz 3 ph W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 118: ...118 WSHP SVX01Y EN Figure 85 GEHE 0 5 to 1 5 tons UC400 W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 119: ...WSHP SVX01Y EN 119 Figure 86 GEHE 2 to 5 tons UC400 W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 122: ...122 WSHP SVX01Y EN N No ot te es s...
Страница 123: ...WSHP SVX01Y EN 123 N No ot te es s...