WARNING
1. Adequate Support Required!
2. The wall/ceiling structure must be adequate to support the weight of the unit. Failure to
ensure adequate structural support could result in the unit falling from its location which
could result in death, serious injury, or equipment or property-only damage.
8
Ceiling Concealed Unit
1. Avoid locating the indoor unit where the return and/or supply air may be obstructed
2. Select a location where it is easy to drain the condensing water and connect to the outdoor unit
3. Keep the indoor unit far away from heat sources, vapor and flammable gas
4. Be sure that the installation of the indoor unit conforms to the installation dimension diagram
5. Be sure to leave enough space to allow access for routine maintenance; clearance between the
bottom of the indoor unit and the floor should not be less than 66"
6. Install in a location where the unit is more than 3 feet away from other electronic appliances such
as television, audio devices, etc.
7. Select a location where air filters can be easily removed and replaced
Installation Location
Indoor Unit
For instructions on installing the outdoor unit please refer to the installation guide
supplied with the selected outdoor unit for your application.