Installation Checklist

 

Check the following points before testing the unit:

NO. 

Item to be checked

Possible problem

1

Have the indoor and outdoor units been 

securely installed?

The units may fall, vibrate or make noise. 

2

Has the refrigerant leak test been 

completed? 

Unresolved leaks may cause insufficient 

cooling or heating. 

3

Have the pipes been properly insulated? 

Lack of insulation may cause condensation 

and water damage. 

4

Is the water condensate drainage 

sufficient?

Lack of proper drainage may cause 

condensation and water damage.

5

Does the voltage of the power supply 

comply with the voltage on the nameplate?

Improper wiring can create malfunction and 

fire or electrocution hazard. 

6

Is the electric wiring and drain piping 

installed correctly? 

Improper wiring and drainage can create 

a malfunction, fire or electrocution hazard 

and water damage to the unit and property.

7

Is the unit grounded properly?

Improper grounding can cause malfunction 

and fire or electrocution hazard. 

8

Does the power cord match the unit 

requirements?

Improper wiring can create malfunction and 

fire or electrocution hazard. 

9

Are there any obstructions near the air 

inlets and air outlets for the indoor and 

outdoor units?

Improper ventilation and airflow will cause 

insufficient cooling and heating. 

10

Have dust and debris been cleaned and 

removed from the installation site? 

Excessive dust and debris in and around 

the units may cause a malfunction or 

damage to the units.

11

Are the gas valve and liquid valve of the 

connection pipes open completely?

Restricted refrigerant flow may cause 

insufficient cooling or heating. 

Test Operation:

1.  Turn on main power to the units. 

2.  Using the remote control, press the ON/OFF button to start operation. 

3.  Press the MODE button to select and test each option for normal operation. Cycle through all 

functions:  AUTO, COOL, DRY, FAN and HEAT.  

4.  Note: If the ambient temperature is lower than 61°F (16°C) the air conditioner will not run in 

COOL mode. 

5.  Go over basic operating, maintenance and troubleshooting functions with the customer. 

24

Ceiling Concealed Unit

Содержание American Standard 4MXD8509A

Страница 1: ...the right to change design and specifications without notice We are committed to using environmentally conscious print practices 2020 MS SVN34D EN 11 Jun 2020 Supersedes MS SVN34C EN January 2016 The...

Страница 2: ...autions Attention Warnings and Cautions appear at appropriate sections throughout this literature Read these carefully WARNING Indicates a potentially hazardous situation which if not avoided could re...

Страница 3: ...contact your local sales office USE ONLYTHE FACTORY RECOMMENDED DAFNE HERMETIC OIL FV50S for servicing these units Important Environmental Concerns Scientific research has shown that certain man made...

Страница 4: ...f the Drain Pipe 14 Design of the Drain Pipe 14 Precautions for the Drain Pipe 15 Test the Drainage System 16 Connecting the Pipe at the Indoor Unit 17 Installation of the Connection Pipe 18 Flare Pro...

Страница 5: ...complete installation may cause injury or property damage in the event the unit falls off of the base 5 Electrical work should be carried out in accordance with the installation manual and local state...

Страница 6: ...ge to the air conditioner 16 Be sure to follow your local state and National Electric Codes when grounding this unit 17 This appliance is not intended for use by persons with a lack of experience and...

Страница 7: ...inch 9 8 inch NOTE Be sure to place an inspection service opening at the position indicated in the diagram above for maintenance of the equipment Indoor Ceiling Concealed Unit NOTE The minimum distanc...

Страница 8: ...e indoor unit far away from heat sources vapor and flammable gas 4 Be sure that the installation of the indoor unit conforms to the installation dimension diagram 5 Be sure to leave enough space to al...

Страница 9: ...e a qualified licensed electrician or other individual who has been trained in handling live electrical components perform these tasks Failure to follow all of the recommended safety warnings provided...

Страница 10: ...ation depends on the actual installation environment After installation of the indoor unit the leveling must be checked to make sure the unit is kept horizontal fore and aft and a downward slope of 5...

Страница 11: ...he transition connection to the air outlet of the unit and attach it with a rivet Connect the outlet to the short duct and secure them with tape CAUTION This unit is intended for free air discharge or...

Страница 12: ...flange is in the back and the return air cover plate is in the bottom 2 If downward return air is desired exchange the location of the rectangular flange and the return air cover plate 3 Connect one e...

Страница 13: ...ge from the joint of the condensate pipe Failure to do so may result in equipment and or property damage 1 The condensate pipe should keep a downward sloping angle of 5 10 which can facilitate drainag...

Страница 14: ...for multiple units the joined section of the pipe should be 3 9 inches 100mm lower than the drain hole of each device and it is suggested to use a larger diameter pipe when connecting multiple units I...

Страница 15: ...accessory Clamp accessory Max 4mm 0 16 inch Precautions for the Drain Pipe The installation height of the lift pipe should be less than 33 5 inches 850mm It is recommended to set an inclination angle...

Страница 16: ...drain pipe should be suitable to the running capacity of the unit Drain Hose accessory Max 75mm Max 1000mm Max 39 4 inch Max 3 inch Test the Drainage System 1 After the electrical installation test t...

Страница 17: ...pe is to be connected so as to prevent dust and impurities from coming into the pipe system Back up Wrench 1 When connecting the pipe to the unit or removing it from the unit please use both the spann...

Страница 18: ...with that of the indoor unit Installation of the Connection Pipe Flare Processing 1 Cut the connection pipe with the pipe cutter and remove the burrs 2 Hold the pipe downward to prevent cuttings from...

Страница 19: ...To prevent breaking of the pipe avoid sharp bends Bend the pipe with a radius of curvature of 5 9 in 150 mm or more 2 If the pipe is bent repeatedly at the same place it will break CAUTION Be sure to...

Страница 20: ...ed insulation 5 All wiring should be done strictly in accordance with the wiring diagram otherwise improper wiring would cause abnormal operation or damage to the unit 6 Do not let the electric wires...

Страница 21: ...rd through the insulation tube fasten it with the cord clamp Stranded Wire Note Match the terminal block numbers and connection cord colors with those of the indoor unit WARNING 1 Before starting work...

Страница 22: ...nd electrocution hazards For high voltage connections flexible electrical conduit is recommended whenever vibration transmission may create a noise problem within the structure To avoid these hazards...

Страница 23: ...The communication distance between the main board and the wired controller can be up to 65 ft The standard distance is 25 ft Note When connecting the power supply cord make sure that the phase of the...

Страница 24: ...malfunction and fire or electrocution hazard 8 Does the power cord match the unit requirements Improper wiring can create malfunction and fire or electrocution hazard 9 Are there any obstructions nea...

Страница 25: ...ck VT Violet OG Orange n Color Key Indoor Unit Ceiling Concealed NOTE The wiring diagrams in this guide are included as a reference The manufacturer has a policy of continuous product and product data...

Страница 26: ...it Dimensions In mm MODEL A B C D E F G H I J 4MXD8509A 30 742 19 491 26 662 24 620 28 700 24 615 31 782 6 156 8 200 25 635 4MXD8512A 4MXD8518A 37 942 19 491 34 862 32 820 35 900 24 615 39 982 6 156 8...

Страница 27: ...hen unit is running or after running The sound of the drainage system operating Cracking sound is heard when unit is operating and after operating This sound occurs when the unit panels expand or cont...

Страница 28: ...roperly 3 If the batteries of the wireless remote controller have been replaced 4 If the filter screen has been cleaned and replaced securely 5 After long periods of shutdown open the main power switc...

Отзывы: