MS-SVN056C-EN
33
Outdoor Unit Installation
Concrete base
•
Mounting base should be 100-300mm/3.94- 11.81 in height above the ground.
•
Install a draining opening around the mounting base.
•
Install the unit to the base with M10 anchor bolts.
•
In installations on the roof or balcony, avoid draining the unit towards areas of human crossing.
100
3.94in
100
̚
300
3.94~1
1.81in
No
Description
Outdoor unit
Rubber protection against vibrations
M10 anchor bolt
Drain (Width 100/3.94in x depth150/5.9in)
Drain
Orifice (
ĭ
100/3.94in x depth 150/5.9in)
1
2
3
4
5
6