Trane 18-HD25D18-3 Скачать руководство пользователя страница 1

INSTALLATION INSTRUCTIONS

69-1787-03

U.S. Patent No. #6595430, D509151 and Other Patents Pending

This thermostat contains a Lithium battery which may contain 

Perchlorate material. Due to State Law in California, the following 

statement is required:

Perchlorate Material—special handling may apply,

See www.dtsc.ca.gov/hazardouswaste/perchlorate

TCONT800AS11AA Touch Screen

Programmable Comfort Control

18-HD25D18-3

APPLICATION

The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating and cooling 
systems. See Table 1 for a general description.

RECYCLE NOTICE

If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 
control in the trash. Dispose of properly.

Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of the old control.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 
the instructions can damage the product or cause 
a hazardous condition.

2.

Installer must be a trained, experienced service 
technician.

3.

After completing installation, use these instructions 
to check out the product operation.

Selecting Location

Install the comfort control about 5 ft. (1.5m) above the 
floor in an area with good air circulation at average 
temperature. See Fig. 1. 

Fig. 1. Selecting comfort control location.

Do not install the comfort control where it can be 
affected by:
— Drafts or dead spots behind doors and in corners.
— Hot or cold air from ducts.
— Radiant heat from sun or appliances.
— Concealed pipes and chimneys.
— Unheated (uncooled) areas such as an outside wall 

behind the comfort control.

Table 1. TCONT800AS11AA Comfort Control Description.

Power Method

Changeover

System Selection

Fan Selection

Comments

24 Vac common wire

Automatic or 
manual 
selectable

Heat-Off-Cool-Auto 

On-Auto-Circ

System and Fan selection vary 
based on system type

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M19925

Содержание 18-HD25D18-3

Страница 1: ...ON When Installing this Product 1 Read these instructions carefully Failure to follow the instructions can damage the product or cause a hazardous condition 2 Installer must be a trained experienced s...

Страница 2: ...l codes and ordinances 1 Select set of terminal identifications Table 2 that corresponds with system type conventional or heat pump in Fig 3 2 Loosen the screws for the appropriate system type selecte...

Страница 3: ...LY PER LOCAL CODES 3 PH ONLY INDOOR OUTDOOR ODT OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR AVAILABLE ON SELECT MODELS WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE 1 1 RC S1 R S2 W1 Y G B H...

Страница 4: ...ng system from shutting down due to lack of battery power it is not recommended that the comfort control be solely powered with the three AAA batteries during normal system operation When using batter...

Страница 5: ...ystem Off both heating and cooling are off Cool controls cooling system Auto automatically changes between heating and cooling systems depending on indoor temperature See Installer Setup section FAN S...

Страница 6: ...nds until screen changes 4 Release the two blank keys when the screen on the comfort control matches the screen below 5 See screen below to review how the comfort control keys are used during Installe...

Страница 7: ...stem Type Selection 0170 1 1 Heat 1 Cool System 1 6 1 1 heat 1 cool 2 single stage heat pump no aux heat 3 heat only no fan 4 heat only with fan 5 hot water Series 20 3 wire or normally open zone valv...

Страница 8: ...gs is disabled 2 Daylight savings is enabled start using in 2007 for areas that use the new 2007 DST calendar Set to 0 in areas that do not follow daylight savings Remote Temperature Sensor Outdoor or...

Страница 9: ...Clock Format 0640 12 12 hour clock format 24 24 hour clock format Extended Fan on time Heat 0650 0 No extended fan operation after call for heat ends 90 Fan operation is extended 90 seconds after cal...

Страница 10: ...ssive temperature control could cause temperature undershoot 3 more aggressive temperature control could cause temperature overshoot Applies to recovery ramp Choose 1 if getting temperature overshoot...

Страница 11: ...ial reading of the indoor or outdoor temperature sensor requires fives minutes to stabilize See the Sensor instructions for installation information CAUTION Equipment Damage Hazard Minimum compressor...

Страница 12: ...etup Number 0670 to change keypad lock options Heating or cooling does not come on Comfort control minimum off time is activated Wait up to five minutes for the system to respond System selection is n...

Отзывы: