35
T23
Series User Manual
For more information about Tramigo tracking products, please visit www.tramigo.com. For distributor, re-seller and
partnership opportunities, email
6.2.15
Ignition
Command:
Ignition,on/off
Alias:
I
Parameters:
on/off - Sets ignition reporting on or off
Description:
Turns ignition reporting on or off for the user.
Related Cmds:
none
Security:
Friend
Message Format:
Command Response
Notes:
1.
The unit must be connected to the ignition circuit to detect when the ignition is turned on
or off. This report is not recommended for portable use as you will receive false ignition
reports.
2.
When using a connection to the ignition circuit set the following parameters:
a.
SET,IgnitionInputShock,0
b.
SET,IgitionInputGPIO,1
3.
You can customize the reporting to include ignition on/off or both. Default is both.
a.
SET,IgnitionOn,1 turns on reporting for ignition on.
b.
SET,IgnitionOff,1 turns on reporting for ignition off.
Errors:
1.
Parameter Error
Examples:
IGNITION,ON
Tramigo: Ignition, reporting turned on, 09:25 Jan 14
IGNITION,OFF
Tramigo: Ignition, reporting turned off, 09:25 Jan 14
When ignition is turned on:
Tramigo: Ignition on detected, parked, 0.15 km NE of Kemaman Hospital,
,Chukai,Terengganu,MY, 09:25 Jan 14
When ignition is turned off:
Tramigo: Ignition off detected, parked, 0.30 km S of Kelab Darul Ehsan,Setapak,KL,MY,