Moisture Encounter Plus

User Guide

Testing on ceramic tiles and other wall and floor coverings.
Excess moisture trapped behind covering materials such as
ceramic tiles, carpet, wall coverings etc can cause major prob-
lems. For instance, excess moisture behind ceramic tiles on
drywall or other substrates can cause decay, delamination and
mold growth, the longer these problems go undetected the worst
the problem can get eventually leading to system failure. 
Your  Moisture Encounter Plus can be used to detect and
identify elevated moisture within or behind most types of wall
and floor coverings. For example the Moisture Encounter Plus
can detect elevated moisture behind most types of ceramic tiles.
As calibration is not practical because of the variation in
composition of these types of construction, tests should be
carried out on a comparative basis selecting the most appropriate
scale, and readings should be taken from the 0 to 100 compara-
tive scale on the meter dial.

Scale 3.
Testing plaster or brick
a) Your  Moisture Encounter Plus gives qualitative (relative)

reading on walls, plaster, brick, drywall and block. Make
sure the appropriate wall scale is used i.e. Scale 2 for drywall
and Scale 3 for plaster or brick. Always press the electrodes
firmly against the surface.

b) The moisture profile of a wall can be determined by sliding

your  Moisture Encounter Plus across the surface where it
will read through most paints, vinyl, wall coverings and even
ceramic tiles.

c) The Moisture Encounter Plus will help identify the different

levels of moisture even if not apparent on the surface.
Moisture can often be trapped behind drywall and wall
covering. 

d) Rising damp and moisture migration from leaks and

defective, or non-existent, vapor barriers can be identified
and profiled and often its source identified by sliding the
instrument across the wall surface.

e) Water damage following flooding or fire fighting can be

checked and the drying out and de-humidification process
can be monitored.

Содержание CME 4

Страница 1: ...g 8 Notes on Specific Gravity SG 9 How to use the Wood SG Tables 9 Wood S G Table 5 to 17 meter reading 10 Wood S G Table 18 to 30 meter reading 11 Scale 2 12 Testing built up roofing 12 Testing Drywa...

Страница 2: ...and sub floors WOOD MOISTURE ENCOUNTER Non destructive testing of wood and wood products PROFESSIONAL MOISTURE METER Digital resistance meter with probes tests deep into wood COMPACT MOISTURE METER E...

Страница 3: ...imately 30 mm 11 4 inches The very small alternating current flowing through the field is inversely proportional to the impedance of the material The instrument detects this current determines its amp...

Страница 4: ...wet and dry Automatic supply timeout 2 minutes conserves battery life Supply timeout is automatically extended if a change in meter reading is detected or if any button is pressed 10 second bleep warn...

Страница 5: ...it is recommended that the PP3 9 volt battery be changed as soon as convenient 2 To change scale press release the SCALE button until the LED opposite the required scale lights 3 Hold your Moisture E...

Страница 6: ...tly to the surface Read the moisture percentage from the top line of the analog dial where calibration is marked from 5 to 30 If switched on the audio signal will sound when readings are above 18 b If...

Страница 7: ...vide an environment for termite and wood boring insects to thrive and multiply Wood at these high levels can also support mold and biological growth Wood at 28 moisture content is considered to have r...

Страница 8: ...rom the concrete causing the wood to swell and buckle and even cause structural damage to the building d When vinyl or other impervious coverings are applied over wet concrete the result can be failur...

Страница 9: ...readings can also be obtained through coverings such as vinyl carpet and laminated wood flooring by using the drywall scale Notes on Specific Gravity SG The SG of wood varies between species and this...

Страница 10: ...6 7 8 8 9 10 11 12 13 14 15 4 5 6 7 8 8 9 10 11 12 13 14 15 4 5 6 7 8 8 9 10 11 12 13 14 15 4 4 6 7 8 8 9 10 11 12 13 14 15 4 4 5 6 7 8 9 10 11 11 12 13 14 4 4 5 6 7 7 8 9 10 11 12 13 14 3 4 5 6 7 7 8...

Страница 11: ...7 18 19 19 20 20 21 23 23 24 15 16 16 17 18 19 19 20 20 21 22 23 23 15 15 15 16 17 18 18 19 20 20 21 22 23 14 15 15 16 17 18 18 19 19 19 20 21 22 14 14 14 15 16 16 17 18 18 19 20 21 21 14 14 14 15 16...

Страница 12: ...t possible to give a calibrated percentage measurement Instead the comparative scale marked 0 to 100 is used for checking the difference between wet and dry d If gravel surfacing is present this shoul...

Страница 13: ...readings should be taken from the 0 to 100 compara tive scale on the meter dial Scale 3 Testing plaster or brick a Your Moisture Encounter Plus gives qualitative relative reading on walls plaster bric...

Страница 14: ...air the defective product without charge for the parts and labour or will provide a replacement in exchange for the defective product returned to Tramex Ltd This warranty shall not apply to any defect...

Страница 15: ...w Product development It is the policy of Tramex to continually improve and update all its products We therefore reserve the right to alter the specification or design of this instrument without prior...

Отзывы: