TrainModules TM-26781 Скачать руководство пользователя страница 22

 

Polarity change current limit 

 

The  booster  can  also  be  used  as  an automatic  reverse loop.  The 
loop reversing  will  automatically  occur in  case  of  sudden  current 
change, provided that automatic polarity change is permitted. 
Enable/ Disable: CV125 (see CV table) 
The  polarity  change  current  limit  can  be  adjusted  between  0.5 A 
and 4 A in 0.1 A steps using the CV129. 
e.g. Required polarity change current limit: 2A 
2A = 20*0.1A => CV129 = 20 
Attention! It is practical to adjust the polarity change current limit 
at a lower value. Thus the sudden "stalling" of the vehicle passing       
along the section can be avoided. In case of polarity change there 
is no short-circuit delay. 

 

 

Programming of the parameters 

 

The  parameters  can  be  modified by  the  DirectCV-programming 
method.  The booster supports the  Write, Read and Verify 
commands. 
For the  application of  this  programming  method  the  "DCC  IN
connector  of the booster must be connected directly to the “PROG 
OUT”  or  normal output  connector  of the  digital  center. During 
programming  attention  must  be  paid to the appropriate  power 
supply of the booster (PWR IN). 
The  booster responds  to  the  center  by  an  ACK  (acknowledge)  for 
identification of the decoder programming, provided that the 
entered value is valid. If after programming the digital  center 
returns an Error, the value entered into the CV is outside the valid 
range, or the address of the CV is not suitable. 

Содержание TM-26781

Страница 1: ...TM 26781 Digitaler Booster Benutzerhandbuch...

Страница 2: ...ur Installation und oder Montage der Ger te ist eventuell ein L tger t erforderlich welches mit besonderer Vorsicht zu handhaben ist Bei der Installation muss gew hrleistet werden dass die Unterseite...

Страница 3: ...hkeit nach Kurzschluss Automat Polarit tswechsel Kehrschleifenmethode Einfach zu tragendes kompaktes Design Technische Parameter Ma e 180 x 100 x 40 mm Stromverbrauch im Standby 40 mA Max Eingangsstro...

Страница 4: ...en Boostern ist es notwendig die Booster mit einem gemeinsamen Erdungspunkt zu betreiben Der Booster ist schwach geerdet wenn er an die LocoNet1 Steckverbindung ange schlossen ist durch 100 kOhm inter...

Страница 5: ...Schienenab schnitts im Vergleich zur Polarit t des vorherigen Abschnitts um gekehrt ist gibt der Booster ein Kurzschluss Signal wenn der Zug die Abschnitte wechselt Ein Booster kann nur zur Verst rkun...

Страница 6: ...m Booster ist ein Entla dungswiderstand 100kOhm Widerstand zwischen Punkt 1 und Punkt 2 des Erdungsanschlusses eingebaut Die Zuordnung des Anschlusses ERDUNG lautet wie folgt 1 LocoNet Erdungspunkt Ke...

Страница 7: ...des laufenden Betriebs bedeutet im Allgemeinen auf nicht ausreichende Erdung und oder einen Transformator mit zu geringer Kapazit t hin ffnen Sie niemals das Ger t wenn der berhitzungsschutz ausge l...

Страница 8: ...zwischen 0 und 60 Sekunden eingerichtet werden Wiederherstellungsverz gerung Bei einem Kurzschluss wird der Booster automatisch zur ckgesetzt Dank der Verz gerung wird der Booster nicht permanent berl...

Страница 9: ...Fahrzeugs verhindert werden Beim Polarit tswechsel tritt keine Kurzschlussverz gerung auf Programmierung der Parameter Die Parameter k nnen mittels der direkten CV Programmierung ge ndert werden Der B...

Страница 10: ...art 0 2 Autom Polarit tswechsel 1 0 3 126 Startverz gerung Sek 2 0 60 127 Wiederherst Verz gerung Sek 5 5 60 128 Kurzschlussausl sestrom Ampere 10 40 5 40 129 Belastungslimit bei Polarit ts wechsel Am...

Страница 11: ...gem er Verwendung und oder Handhabung ung ltig Achtung Laut der europ ischen EMV Richtlinien darf das Produkt lediglich mit Ger ten verwendet werden die ber eine CE Kenn zeichnung verf gen Die erw hnt...

Страница 12: ...Abbildung 1 Schaltplan des digitalen Boosters TM 26781 POWER SVNO Previous section Roco Lenz Booster JUI Booster out...

Страница 13: ...Abbildung 2 Netzwerk bei gro en Anlagen Ground...

Страница 14: ...TM 26781 Digital booster User s manual...

Страница 15: ...may be necessary for the installation and or mounting of the devices which requires special care During the installation it shall be ensured that the bottom of the device should not contact with a con...

Страница 16: ...tomatic reversal of polarization loop reversing method Easily portable compact design Technical parameters Dimensions 180 x 100 x 40 mm Idle mode current consumption 40 mA Max input current 5000 mA Sh...

Страница 17: ...h contain more boosters it is required to operate the boosters with a common grounding point The booster is weakly grounded by 100 kOhm internal resistor when it is connected to the LocoNet 1 terminal...

Страница 18: ...section is of reversed polarity compared to the previous section the booster will give a short circuit signal when the train changes the sections One booster can only be used for one single signal The...

Страница 19: ...discharge resistor 100K resistance is integrated between point 1 and point 2 of its GROUND connector The assignment of the GROUND connector is as follows 1 LocoNet grounding point core 2 and 5 2 Inte...

Страница 20: ...ermal protection during running operation generally means insufficient wiring and or a low capacity transformer Never open the device when the thermal protection has been triggered Switching in out of...

Страница 21: ...up delay can be adjusted between 0 and 60 sec by the CV126 in one second steps Recovery delay In case of short circuit the booster automatically resets Due to the delay the booster will not be permane...

Страница 22: ...ded In case of polarity change there is no short circuit delay Programming of the parameters The parameters can be modified by the DirectCV programming method The booster supports the Write Read and V...

Страница 23: ...n mode 0 0 1 125 Configuration 0 1 Automatic restart 0 2 Automatic polarity change 1 0 3 126 Start up delay sec 2 0 60 127 Recovery delay sec 5 5 60 128 Short circuit tripping current Ampere 10 40 5 4...

Страница 24: ...guarantee will cease in case of improper usage and or treatment Attention By virtue of the European EMC directives the product can be used solely with devices provided with CE marking The mentioned st...

Страница 25: ...Figure 1 Wiring of digital booster TM 26781 POWER SVNO Previous section Roco Lenz Booster JUI Booster out...

Страница 26: ...Flgure 2 Large Iayout network grounding Ground...

Отзывы: