Configuration and Powering On
Configuring the IR Receiver
To turn the unit on or select the mode of
operation, use a paperclip to press and hold the
configuration button. The LCD display will
sequence through the available operation modes
of the SIDE, set FRNT, set DUAL, SELFTEST, or
PWR OFF. To select the desired mode, release
the button when the display indicates the mode.
To put the counter into Alignment Mode,
momentarily press and release the configuration
button on the IR Receiver. If the IR Receiver and
IR Transmitter are properly aligned, then the LED will be lit on the IR Receiver. You can
exit Alignment Mode by pressing the Configuration Button again or allow it to exit
Alignment Mode on its own (after 60 seconds). This button is also used to send a service
packet. This will be discussed later in the manual.
IR Range (Low Power) 0.5 Feet to 10 Feet
IR Range (High Power) 10 Feet to 20 Feet
To display the counts on the LCD
1.) Momentarily press the configuration button or 2.) Swipe a magnet across the IR
Receiver where the reed switch is located (opposite side of the LCD display).
To
reset the counts to zero, hold a magnet next to the reed switch for
approximately 5 seconds. This is the only way to reset the counts. It is
recommended that you use your magnet to check your counts. This will
eliminate the potential of changing the configuration or possibly turning off the
sensors.