MIU-1500 / CompuCount User’s Guide
Page 16
Viewing
- continued
Sensor Types
*3, date, time, sensor type1,
…sensor typen
date
– date that the report was generated.
time
– time that the report was generated.
sensor type
– type of sensor: 1 – Traf-Sys Peoplecounter; 2 – Mighty-Might or Directional
Counter
n
– number of sensors
Sensor Period A Counts
7, date, time, countA1,
…countAn
date
– date of the period.
time
– time of the period.
countA
– count for the period for the first set of counts for the sensor. The period is either 30
minutes or 1 day
n
– number of sensors
Sample record:
7,01/17/03,00:00:00,127,115
Sensor Current Interval A Counts
8, date, time, countA1,
…countAn
date
– date of the current interval.. This is a partial total for the interval, as the current interval has
not been completed yet.
time
– time of the current interval.. This is a partial total for the interval, as the current interval has
not been completed yet.
countA
– count for the current interval for the first set of counts for the sensor.
n
– number of sensors
Sample record:
8,01/20/03,00:00:00,176,147,142,1,3,353
Sensor Period B Counts
*9, date, time, countB1,
…countBn
date
– date of the period.
time
– time of the period.
countB
– count for the period for the second set of counts for the sensor.. The period is either 30
minutes or 1 day
n
– number of sensors