Maintenance

 

Before Each Use 

 

Regular periodic maintenance on your Air Compressor will ensure its optimum performance. Make a habit of 

inspecting the following items before each time you use the air compressor. 

 

Check the following items: 

1. Check Oil Level! 

Use the sight gauge on the bottom of the crankcase to make sure the oil level is at the proper 

height. 

2. 

Drain the tanks of any condensation by opening the drain valve on the bottom of the tank. Note

Depending upon 

the amount of use and the weather conditions, a certain amount of condensed water may be released. 

For longevity of the compressor seals and the air tools you connect, it is best to keep the tank free of water. The tank 

is best drained if the drain valve is opened when the system is slightly pressurized. Once water has stopped coming 

out, you can close the drain valve. 

3

. Clean off cylinder head cooling fins of any dirt which might hamper air flow. 

4. 

Check for worn or damaged cords and plugs. 

5. 

Check for any other condition that could hamper the safe operation of the compressor. 

 

Caution

” Please refer any maintenance of Vee-belts, pressure switches, electrical components and pump 

to qualified compressor technicians. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание MCFRC227

Страница 1: ...ESSOR MCFRC234 3HP 200LT BELT DRIVE COMPRESSOR W TYPE CAST IRON PUMP THREE PHASE RANGE PE50300 5 5HP 270LT BELT DRIVE COMPRESSOR PE75300 7 5HP 270LT 2STAGE BELT DRIVE COMPRESSOR PE100300 10HP 270LT 2S...

Страница 2: ...tual product supplied The design of our products is subject to change without notice Our company is available to offer telephonic support in the event of any conflict occurring between this manual and...

Страница 3: ......

Страница 4: ...X Couplers 2PC X Couplers 2PC X Couplers 2PC X Couplers 2PC X Couplers 2PC X Couplers 2PC X Couplers Packge size cm 93x38x73 105x42x86 105x42x86 131x45x96 136x50x103 105x42x86 131x45x96 136x50x103 G W...

Страница 5: ...ystems and components as well as safety precautions is necessary before operating or maintaining the compressor If the user fails to follow the operation and maintenance procedures contained in this m...

Страница 6: ...e warranty clause of the original manufacturer shall be directly applied in feasible conditions Within the warranty period TRADEair or its agent shall be informed in writing within 30 days of the defe...

Страница 7: ...or transport damages C Failing to follow the stipulations contained in the operation instructions regulations or other special sales conditions D Labour and transportation costs losses or damages cau...

Страница 8: ...may cause general damages to the machines or injuries Warning describes unsafe factors which may cause property loss or injuries Danger describes unsafe factors of a mechanical nature which may cause...

Страница 9: ...essor in conjunction with the risks stated in the Chapter Safety Rules Before delivering the machine clear warning labels have been attached to the places where risks are present and places requiring...

Страница 10: ...in the shop or when taking the air compressor to a job site the most important consideration is access to an adequate and properly fused power supply Also make sure the compressor is not operating in...

Страница 11: ...condition if problems occur to the unit do not attempt to restart the unit until the fault has been corrected The power supply shall be shut off and significant indication signs shall be positioned to...

Страница 12: ...E CRANKCASE Oil has NOT been supplied in your air compressor The oil level should be in the center of the oil sight gauge on the pump Use proper compressor oil only See figure 1 below Figure 1 Oil lev...

Страница 13: ...k of fire hazard due to overheating Be sure to use a compressor capable of handling the air demand Operating the unit To start the air compressor 1 Make sure the compressor switch is in the OFF positi...

Страница 14: ...istant lenses they are not safety glasses Be certain the safety glasses you wear meet the appropriate standards 1 Close the drain valve shown in Figure 3 so the tank can build up pressure 2 Double che...

Страница 15: ...knob shown in Figure 5 to set the pressure that will be delivered to your tool Turn the knob clockwise to increase the pressure and counter clockwise to decrease the pressure Figure 5 Air control kno...

Страница 16: ...aches 8 8 BAR for MCFRC230 231 232 233 234 238 239 227 228 229 and PE50300 13 5 BAR for PE75300 PE 100300 PE100500 and PE150500 To manually release the air in the tank by using the safety valve 1 Loca...

Страница 17: ...ools To connect air tools to your air compressor 1 Make sure the compressor model you use has a sufficient volume in output for the air tool you plan to connect Most air tools will have an air require...

Страница 18: ...e compressor to maintain pressure A paint sprayer or grinder tends to use a more continuous stream of air as these tools are run for longer time periods It is always better to oversize a compressor to...

Страница 19: ...the weather conditions a certain amount of condensed water may be released For longevity of the compressor seals and the air tools you connect it is best to keep the tank free of water The tank is be...

Страница 20: ...e below If you are unsure of this refer the unit to a qualified compressor technician Remove the air filter foam element and rinse it out with water Allow it to dry and re install Blow out any accumul...

Страница 21: ...ittings Storage when not in use When storing your air compressor follow these guidelines 1 Set the ON OFF button to OFF 2 Turn the regulator counter clockwise to set the delivery pressure to zero 3 Di...

Отзывы: