5.1.2. Automatic zero
On power up, the display will indicate "0" so long as the force measured
is less than 10 % of the maximum capacity of the device.
5.2. BASIC FUNCTIONS
5.2.1. Tare function
Nbr
DISPLAY
REMARKS
1
daN
kg
Ibs
Net
Gr.
Device ready to operate.
No load suspended
"Gr" indicator (GROSS measurement)
activated.
2
daN
kg
Ibs
Net
Gr.
A 25 kg recipient is currently suspended.
3
daN
kg
Ibs
Net
Gr.
The operator presses 2 seconds on the
TARE button.
The value of the weight currently
measured is stored.
The display goes to "0.0".
The "Net" indicator is activated.
4
daN
kg
Ibs
Net
Gr.
The operator loads 55 kg of equipment
in the recipient.
The display indicates 55, i.e. the NET
weight.
5
daN
kg
Ibs
Net
Gr.
The operator presses the TARE button.
The display indicates 80, i.e. the GROSS
weight.
The "Net" indicator is deactivated; the "Gr."
indicator is activated.
6
daN
kg
Ibs
Net
Gr.
The operator presses the TARE button.
The display indicates 55.0, i.e. the NET
weight.
By successively pressing the TARE button,
the display switches back and forth the
"Net" and the "Gr." indicators.
The load can be increased in both
conditions; the difference between
"GROSS" and "NET" will always be the
weight stored in step 3.
7
daN
kg
Ibs
Net
Gr.
If the operator presses the TARE button
for 2 seconds.
New Tare: Return to step 3.
The function is reinitiated (return to step 1)
when the device is switched off.