1.  DEFINITIONS 

In this manual, the following terms mean:  
 
« Product » :  

Equipment element or assembly defined on the cover page, delivered 

complete in its standard version, or as one of the various models described.  
 
« Installation » :  

Comprehensive set of operations required to place a complete product in a 

condition ready for commissioning (or connection to other components for commissioning), 
starting from the state in which the product has been delivered.  
 
« User » :  

 

Person or department responsible for the management and safe use of the 

product described in the manual.  
 
« Technician » :  

Qualified person in charge of the maintenance operations described and 

authorized to the user by the manual ; the technician is understood to be skilled and familiar 
with the product.  
 
« Operator » :  

Person or department using the product in compliance with the purpose for 

which it is intended. 

 

2.  PICTOGRAMS USED IN THIS MANUAL 

 

«DANGER»: Remarks intended to prevent fatal, serious or minor injury to 
personnel or damage to the environment. 

 

«IMPORTANT»: Remarks intended to prevent a failure or damage to the 
product,  but  not  directly  endangering  the  life  or  health  of  the  operator  or 
any other person, or damage to the environment 

 

You must read the user and maintenance manual. 

 

3.  STANDARD CONTENT OF DELIVERY

 

  A Tension meter dynarope HF 36/3 LPT 

  A display HF 87/T/LPT with 3 "AA" 1,5 V batteries  

  A LEMO connection cable 4 poles 

  A USB key with the LOADER Light program and a USB-Mini USB connection cable 

  A CE certificate & calibration certificate 

  A user manual 

 

 

A rugged carrying box  

 

 

Содержание Dynarope HF36/3/LPT

Страница 1: ...0 Tension meter dynarope HF36 3 LPT EN Operation and maintenance manual ...

Страница 2: ... 7 5 3 Display information and keyboard functions 8 6 TO CARRY A MEASUREMENT OUT 9 6 1 To install the tension meter on the wire rope 10 7 CONFIGURATION MENU 11 8 ADVANCED FUNCTIONS 12 8 1 Average 12 8 2 Record 13 8 3 Custom calibration 13 8 4 1 Create 13 8 4 2 Use 14 8 4 Monitor 14 9 MAINTENANCE CHECKING AND CLEANING 15 9 1 Changing batteries 15 9 2 Regulatory check 15 9 3 Maintenance 15 10 MESSAG...

Страница 3: ...ted on the unit It must never be used in explosive atmospheres 8 This appliance should never be used for man riding applications without a thorough prior check that the utilization coefficients required for personnel safety have been applied and more generally that the safety regulations for the load line on which it has been installed have been applied 9 Tractel declines any responsibility for us...

Страница 4: ...the manual the technician is understood to be skilled and familiar with the product Operator Person or department using the product in compliance with the purpose for which it is intended 2 PICTOGRAMS USED IN THIS MANUAL DANGER Remarks intended to prevent fatal serious or minor injury to personnel or damage to the environment IMPORTANT Remarks intended to prevent a failure or damage to the product...

Страница 5: ...m Weight of the HF 36 3 LPT in its transport case 37 kg Net weight of the device 15 kg Power supply 3 AA alkaline cells located into the display Note for efforts above 20 tons we strongly recommend to purchase the hydraulic assistance Precision obtained with the provided cable samples on a BELAC accredited test bench according to the method PL LAB 07 4 3 Data bank HF 36 3 LPT The Standard data ban...

Страница 6: ...36 1 4173 3 1000 22000 13 5037 Steel 6 x 36 40 1 5748 3 1000 22000 14 5038 Steel 6 x 36 42 1 6535 3 1000 22000 15 5039 Steel 6 x 36 44 1 7323 3 1000 22000 16 5040 Steel 8 x 19 24 15 16 0 9449 1 500 11000 17 5041 Steel 8 x 19 26 1 0236 1 500 12000 18 5042 Steel 8 x 19 28 1 1 8 1 1024 2 500 14000 19 5043 Steel 37 x 1 20 0 7874 2 1000 10000 20 5044 Steel 37 x 1 22 0 8661 2 1000 15000 21 5045 Steel 37...

Страница 7: ... stop block F Axle of the sheave L LEMO cable LEMO connector is a push pull connector The LEMO self latching system allows the connector to be mated or unmated by simply pushing or pulling axially on the outer release sleeve Any rotation of the plug while in the socket will damage the connector and hence the connection between the sensor and the display H E D C B A G F K I J L ...

Страница 8: ... Batteries cover LEMO connector is a push pull connector The LEMO self latching system allows the connector to be mated or unmated by simply pushing or pulling axially on the outer release sleeve Any rotation of the plug while in the socket will damage the connector and hence the connection between the sensor and the display B A C D F E H G ...

Страница 9: ... off keeps the device on In MENU Mode Press scroll up I F2 Key Press access to wire rope data bank Press 3 sec access to historical In MENU Mode Press Select J key Press 3 sec Backlight on or off Press data log In MENU Mode Press scroll down K Key Press ON Press 3 sec OFF When ON Press access to MENU In MENU Mode Press Enter L F1 Key Press average mode on Press 3 sec monitor mode on Press 3 sec cu...

Страница 10: ... the type of tension meter presently connected to your display e g 36 3 o Scroll with keys or T o Valid with key Select the references of the wire rope you want to control o Press F2 to accede at the data bank o Scroll with keys or T calibration reference number wire rope diameter Material Structure e g Note Press F2 for 3 sec to visualize the historical of the previous selections o Valid your sel...

Страница 11: ... range of the selected cable 6 1 To install the tension meter on the wire rope Use the crank in order to unscrew the tightening screw Place the two sheaves onto the wire rope Use the crank to tight the tightening screw until the wire rope gets in firm contact with the rotary stop block Once the cable is in contact with the rotary stop block confirm with a of turn without forcing it Excessive torqu...

Страница 12: ...RMATION RESTORE RECORDS READ DELETE UNITS LOAD G DIAMETER TEMPERATURE PARAMETERS o LANGUAGE Available languages are French and English o AUTO OFF Setting from 0 up to 60 minutes o BACKLIGHT Setting from 0 up to 60 minutes o TIME Set your local time o DATE Set your local date o INFORMATION About the display o RESTORE To restore the factory setting Except TIME and DATE ...

Страница 13: ...average tension from up to 5 consecutive measures While taking a measure press F1 during 2 seconds to activate the average mode The current effort is displayed on the main screen and on the bottom you can read o AVG the average effort 1 which indicates that the average is captured from only 1 measure Take another measurement and shortly press on F1 to add this second measure to the computation of ...

Страница 14: ...e installation and apply the desired tension in the cable Before placing the tension meter on the cable determine the position of the stop block according to a cable of similar characteristics see 4 5 Database Press F2 and select the cable Special first line of the list Select a blank line Spc xx Press F2 Select Calibrate with key to create a new calibration o Use see 8 3 2 o Delete to delete an e...

Страница 15: ...on allows you to launch an automatic acquisition sequence i e recording during a specified period at a specified interval variations of effort on a cable maximum 999 acquisitions The operating data recorded via the monitor function requires LOADER MONITOR software option Press 3 sec to turn Monitor mode on Set the interval time in seconds from 1 to 60 with the keys T and Validate with The automati...

Страница 16: ...ppliance 9 3 Maintenance The sensor display unit requires no specific maintenance other than a regular cleaning with a dry cloth 10 MESSAGES 10 1 Information messages Message Cause Solution No wire rope selected Select a wire rope 6 MIN Current effort is below the measurement range of the selected wire rope Apply tension in the wire rope MAX Current effort is above the measurement range of the sel...

Страница 17: ...or Unidentified error Consult the manufacturer See conditions 8 1 8 2 or 8 4 See 8 1 8 2 or 8 4 AD L The output signal from the tension meter is too low Consult the manufacturer AD H The output signal from the tension meter is too high Verify that the sensor is not overloaded Consult the manufacturer Z er The system cannot zeroing Connection problem between the tension meter and the display Connec...

Страница 18: ...eters range 4 Maximal capacity 5 Protection rating 6 Power supply 7 Symbol Read the instruction Manual 1 2 3 5 4 6 2 5 7 6 Made in Belgium HF 36 3 LPT n XXXXXX Ø 20 44 mm 0 7874 to 1 7323 in t 40000 daN 89600 lbs IP 65 Made in Belgium HF 87 T LPT n XXXXXX IP 65 AA 1 5 VDC x 3 1 ...