14
8.4.2 Use
•
Press F2 and select the cable -- Special -- (first line of the list)
•
Select an existing custom calibration
o
Select “Use” with key
to use the custom calibration
•
Turn the stop block on the displayed position and confirm the setting with
(see § 6)
•
The display shows the current effort with, at the bottom left of the screen, the reference
of the selected custom calibration and the value of the calibration
The effort will only be accurate at this calibration value. At any other value, the
precision cannot be guaranteed.
8.4. Monitor
The monitor function allows you to launch an automatic acquisition sequence, i.e. recording
during a specified period at a specified interval, variations of effort on a cable (maximum 999
acquisitions).
The operating data recorded via the monitor function requires LOADER MONITOR software
option.
•
Press 3 sec to turn Monitor mode on
•
Set the interval time in seconds (from 1 to 60) with the keys T and
•
Validate with
The automatic recording has started and is displayed at the bottom left of the screen :
The countdown till the next recording (based on the set interval) – current measure –
between brackets the number of measurements recorded
•
Press F1 for 3 sec to leave the Monitor mode
Note: the effort must be an actual value (neither "MIN" nor "MAX”) otherwise, the error message
“!” appears.