PRIORITY INSTRUCTIONS 

 

1.  Before installing and using this unit, to ensure safe, efficient use of the unit, be sure you have read 

and  fully  understood  the  information  and  instructions  given  in  this  manual.  A  copy  of  this  manual 
should be made available to every operator. Extra copies of this manual can be supplied on request. 

2.  Do not use the unit if any of the plates mounted on the unit are missing or if any of the information on 

the  plates,  as  indicated  at  the  end  of  the  manual,  are  no  longer  legible.  Identical  plates  will  be 
supplied on request; these must be secured on the unit before it can be used again. 

3.  Make  sure  that  all  persons  operating  this  unit  know  perfectly  how  to  use  it  in  a  safe  way,  in 

observance of all safety at work regulations. This manual must be made available to all users. 

4.  The  positioning  and  commissioning  of  this  appliance  must  be  carried  out  under  conditions  that 

ensure installer safety in compliance with the relevant regulations. 

5.  Each time, before using the unit, inspect the unit for any visible damage, as well as the accessories 

used  with  the  unit.  Never  use  an  appliance  that  is  not  obviously  in  good  condition.  Returns  the 
appliance to the manufacturer for servicing if any anomalies arise that have no connection with the 
state of the battery; 

6.  Protect your appliance from any form of impact, especially the display unit. 

7.  The unit must never be used for any operations other than those described in this manual. The unit 

must  never  be  used  to  handle  any  loads  exceeding  the  maximum  utilization  load  indicated  on  the 
unit. It must never be used in explosive atmospheres. 

8.  This appliance should never be used for man-riding applications without a thorough prior check that 

the utilization coefficients required for personnel safety have been applied, and more generally that 
the safety regulations for the load line on which it has been installed have been applied. 

9.  Tractel® declines any responsibility for use of this unit in a setup configuration not described in this 

manual. 

10. Tractel®  declines  any  responsibility  for  the  consequences  of  any  changes  made  to  the  unit  or 

removal of parts. 

11. Tractel® declines any responsibility for the consequences resulting from disassembly of the unit in 

any way not described in this manual or repairs performed without Tractel® authorization, especially 
as concerns replacement of original parts by parts of another manufacturer. 

12. If the unit is to be definitively removed from use, make sure the unit is discarded in a way which will 

prevent any possible use of the unit. All environment protection regulations must be observed. 

13. Any operation of this appliance in conjunction with supplementary equipment relaying signals on an 

operating  system  must  be  preceded  by  a  risk  analysis  related  to  the  operating  functions 
implemented, carried out by the system user or assembler, and all appropriate measures are taken 
as a consequence. 

14. Certified in compliance with European regulations, this appliance should be checked for compliance 

with the regulations of any other country where it might be used, prior to being commissioned there. 

 

 

As part of the continuous improvement of the quality of its products, TRACTEL® 
reserves the right to change, without notice, the characteristics of the products covered 
in this manual. 

Содержание Dynarope HF36/3/LPT

Страница 1: ...0 Tension meter dynarope HF36 3 LPT EN Operation and maintenance manual ...

Страница 2: ... 7 5 3 Display information and keyboard functions 8 6 TO CARRY A MEASUREMENT OUT 9 6 1 To install the tension meter on the wire rope 10 7 CONFIGURATION MENU 11 8 ADVANCED FUNCTIONS 12 8 1 Average 12 8 2 Record 13 8 3 Custom calibration 13 8 4 1 Create 13 8 4 2 Use 14 8 4 Monitor 14 9 MAINTENANCE CHECKING AND CLEANING 15 9 1 Changing batteries 15 9 2 Regulatory check 15 9 3 Maintenance 15 10 MESSAG...

Страница 3: ...ted on the unit It must never be used in explosive atmospheres 8 This appliance should never be used for man riding applications without a thorough prior check that the utilization coefficients required for personnel safety have been applied and more generally that the safety regulations for the load line on which it has been installed have been applied 9 Tractel declines any responsibility for us...

Страница 4: ...the manual the technician is understood to be skilled and familiar with the product Operator Person or department using the product in compliance with the purpose for which it is intended 2 PICTOGRAMS USED IN THIS MANUAL DANGER Remarks intended to prevent fatal serious or minor injury to personnel or damage to the environment IMPORTANT Remarks intended to prevent a failure or damage to the product...

Страница 5: ...m Weight of the HF 36 3 LPT in its transport case 37 kg Net weight of the device 15 kg Power supply 3 AA alkaline cells located into the display Note for efforts above 20 tons we strongly recommend to purchase the hydraulic assistance Precision obtained with the provided cable samples on a BELAC accredited test bench according to the method PL LAB 07 4 3 Data bank HF 36 3 LPT The Standard data ban...

Страница 6: ...36 1 4173 3 1000 22000 13 5037 Steel 6 x 36 40 1 5748 3 1000 22000 14 5038 Steel 6 x 36 42 1 6535 3 1000 22000 15 5039 Steel 6 x 36 44 1 7323 3 1000 22000 16 5040 Steel 8 x 19 24 15 16 0 9449 1 500 11000 17 5041 Steel 8 x 19 26 1 0236 1 500 12000 18 5042 Steel 8 x 19 28 1 1 8 1 1024 2 500 14000 19 5043 Steel 37 x 1 20 0 7874 2 1000 10000 20 5044 Steel 37 x 1 22 0 8661 2 1000 15000 21 5045 Steel 37...

Страница 7: ... stop block F Axle of the sheave L LEMO cable LEMO connector is a push pull connector The LEMO self latching system allows the connector to be mated or unmated by simply pushing or pulling axially on the outer release sleeve Any rotation of the plug while in the socket will damage the connector and hence the connection between the sensor and the display H E D C B A G F K I J L ...

Страница 8: ... Batteries cover LEMO connector is a push pull connector The LEMO self latching system allows the connector to be mated or unmated by simply pushing or pulling axially on the outer release sleeve Any rotation of the plug while in the socket will damage the connector and hence the connection between the sensor and the display B A C D F E H G ...

Страница 9: ... off keeps the device on In MENU Mode Press scroll up I F2 Key Press access to wire rope data bank Press 3 sec access to historical In MENU Mode Press Select J key Press 3 sec Backlight on or off Press data log In MENU Mode Press scroll down K Key Press ON Press 3 sec OFF When ON Press access to MENU In MENU Mode Press Enter L F1 Key Press average mode on Press 3 sec monitor mode on Press 3 sec cu...

Страница 10: ... the type of tension meter presently connected to your display e g 36 3 o Scroll with keys or T o Valid with key Select the references of the wire rope you want to control o Press F2 to accede at the data bank o Scroll with keys or T calibration reference number wire rope diameter Material Structure e g Note Press F2 for 3 sec to visualize the historical of the previous selections o Valid your sel...

Страница 11: ... range of the selected cable 6 1 To install the tension meter on the wire rope Use the crank in order to unscrew the tightening screw Place the two sheaves onto the wire rope Use the crank to tight the tightening screw until the wire rope gets in firm contact with the rotary stop block Once the cable is in contact with the rotary stop block confirm with a of turn without forcing it Excessive torqu...

Страница 12: ...RMATION RESTORE RECORDS READ DELETE UNITS LOAD G DIAMETER TEMPERATURE PARAMETERS o LANGUAGE Available languages are French and English o AUTO OFF Setting from 0 up to 60 minutes o BACKLIGHT Setting from 0 up to 60 minutes o TIME Set your local time o DATE Set your local date o INFORMATION About the display o RESTORE To restore the factory setting Except TIME and DATE ...

Страница 13: ...average tension from up to 5 consecutive measures While taking a measure press F1 during 2 seconds to activate the average mode The current effort is displayed on the main screen and on the bottom you can read o AVG the average effort 1 which indicates that the average is captured from only 1 measure Take another measurement and shortly press on F1 to add this second measure to the computation of ...

Страница 14: ...e installation and apply the desired tension in the cable Before placing the tension meter on the cable determine the position of the stop block according to a cable of similar characteristics see 4 5 Database Press F2 and select the cable Special first line of the list Select a blank line Spc xx Press F2 Select Calibrate with key to create a new calibration o Use see 8 3 2 o Delete to delete an e...

Страница 15: ...on allows you to launch an automatic acquisition sequence i e recording during a specified period at a specified interval variations of effort on a cable maximum 999 acquisitions The operating data recorded via the monitor function requires LOADER MONITOR software option Press 3 sec to turn Monitor mode on Set the interval time in seconds from 1 to 60 with the keys T and Validate with The automati...

Страница 16: ...ppliance 9 3 Maintenance The sensor display unit requires no specific maintenance other than a regular cleaning with a dry cloth 10 MESSAGES 10 1 Information messages Message Cause Solution No wire rope selected Select a wire rope 6 MIN Current effort is below the measurement range of the selected wire rope Apply tension in the wire rope MAX Current effort is above the measurement range of the sel...

Страница 17: ...or Unidentified error Consult the manufacturer See conditions 8 1 8 2 or 8 4 See 8 1 8 2 or 8 4 AD L The output signal from the tension meter is too low Consult the manufacturer AD H The output signal from the tension meter is too high Verify that the sensor is not overloaded Consult the manufacturer Z er The system cannot zeroing Connection problem between the tension meter and the display Connec...

Страница 18: ...eters range 4 Maximal capacity 5 Protection rating 6 Power supply 7 Symbol Read the instruction Manual 1 2 3 5 4 6 2 5 7 6 Made in Belgium HF 36 3 LPT n XXXXXX Ø 20 44 mm 0 7874 to 1 7323 in t 40000 daN 89600 lbs IP 65 Made in Belgium HF 87 T LPT n XXXXXX IP 65 AA 1 5 VDC x 3 1 ...

Отзывы: