Fuse 

 

 

Recommended fuse holders and fuses for installation up to 48V supply 

voltages (can be ordered at Trackunit A/S): 

a.  Supply voltage 12V/24V (Max 30A)  

  i.  ATO blade fuses (Max 32V/1A) used with Littelfuse FHAC0002SXJ fuse 

holder (standard). 

  ii.   ATP blade fuse (Max 32V/1A - ATO style) used with TaiTek FH-

006WR-12R-12-U fuse holder (standard).   

b.  Supply voltage 12V - 48V (Max 30A) 

  i.  FKS blade fuse (Max 80V/3A - ATO style) used with Littelfuse FH2 fuse 

holder (recommended). 

 

 

Machinery 

 

 

The TU501 products comply with the essential requirements of the Directive 

2006/42/EC and EU regulation 167/2013 when integrated as intended: 

 

I.  EN 13309 Construction machinery 

II.  ISO 13766 Earth-moving machinery 

III.  EN/ISO 14982 Agricultural and forestry machines.  

IV.  UN regulative ECE R10 EMC rev. 4 in accordance with EU regulation 

661/2009 for Electronic Sub-Assembly (ESA). 

 

NOTE: Harmonized standards under the directive 2014/30/EU have been 

applied. 

 

  

 

 

Содержание TU501 Series

Страница 1: ...NOTE Former model ID was ME501 x 2G 3G Model ID changed in 2017 to TU501 x 2G 3G Short guide TU501 x Version 4 2 May 2019...

Страница 2: ...allation example 5 Functionality check LED on the unit 6 Installation check and update using Verify my Trackunit 7 Input filtering INFILT 8 CAN bus termination resistor 9 Troubleshooting 10 Product sp...

Страница 3: ...is located on the unit The mobile number and unit serial number are located on the box label It can be peeled off and saved for later use Do not perform installation inside a building Install the uni...

Страница 4: ...1 Digital input 3 Optional input1 Digital input 4 Can be used for INFILT function Optional input2 Digital output 1 Can be used to control a relay3 4 Additional input for TU501 2 1 Wire input M8 connec...

Страница 5: ...TU501 x Short Guide TU501 x v4 2 May 2019 Trackunit 2019 5 Installation example...

Страница 6: ...is OK and GPS has valid satellite position No light in LED No power supply Constant red light and no green light in LED Power supply is OK but NO mobile network GPS has NO satellite position Red flas...

Страница 7: ...GPS and mobile signal Mobile number Power supply voltage Internal battery voltage Status of inputs 1 4 on off Click Find again to refresh status Step 4 Basic configuration options Enter a device name...

Страница 8: ...rs To avoid this situation the digital input 4 pink wire should be connected to the chassis ground on the machine The infilt function should be activated via Verify my Trackunit Activation of input fi...

Страница 9: ...ller or if the TU501 4 is to be installed as a stub on a CAN bus with multiple CAN devices already attached The 120 ohm termination resister is a permanently installed resistor so make sure to use and...

Страница 10: ...g operating hours when machine is off Possibly due to the main breaker being on the negative wire ground wire from the machine battery When off the inputs may register a voltage level and start counti...

Страница 11: ...pply voltage 12 48 V DC Absolute maximum voltage range 8 58 V DC continuous Standby consumption GSM receiver active 10 mA 7 mA avg at 12V 24V Consumption during charging an empty battery 225 mA 115 mA...

Страница 12: ...is either machinery or battery powered Storage 40 C to 70 C Shorter battery lifetime must be expected when storage and operation occur at extreme temperatures Mechanical specifications Length 106 mm...

Страница 13: ...C rules and with RSS GEN RSS 132 RSS 133 RSS 210 and ICES 003 of the Industry Canada requirements Environmental The TU501 products comply with the environmental conditions for rolling stock and transp...

Страница 14: ...dard b Supply voltage 12V 48V Max 30A i FKS blade fuse Max 80V 3A ATO style used with Littelfuse FH2 fuse holder recommended Machinery The TU501 products comply with the essential requirements of the...

Страница 15: ...C IC Radiofrequency radiation exposure Information This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment may be installed and operated...

Страница 16: ...unit ME501 9 New model ID TU501 9 Japan ID n R 003 150064 T D150059003 This device is granted pursuant to the Japanese Radio Law This device should not be modified otherwise the granted designation nu...

Отзывы: