background image

TU501-x 

 

 

 

Short Guide TU501-x v4.2, May 2019, ©Trackunit 2019

 

 

13 

 

Regulatory information and precautions 

 

 

Use location 

 

 

This equipment design applies to commercial or industrial equipment 

expected to be installed in locations where only adults are normally present 

 

 
Terms of use 
 

 

Use only Trackunit approved accessories and/or batteries. Do not connect 

incompatible products 

 

 
New battery 
 

 

In case of battery malfunction, expiration or any other situation where a new 

battery might be needed, replacement batteries can be ordered through 

[email protected]

 

 

 

CE mark

  

 

The TU501 products comply with the essential requirements of the RED 

2014/53/EU directive with respect to the EMC requirements, safety and radio 

spectrum matters. 

 

 

FCC mark 

 

 

The TU501 products contain radio transmitters and comply with the essential 

requirements of Part 15, 22 and 24 of the FCC rules, and with RSS-GEN, 

RSS-132, RSS-133, RSS-210 and ICES-003 of the Industry Canada 

requirements. 

 

 
Environmental  

 
The TU501 products comply with the environmental conditions for rolling 

stock and transportation according to DIN EN 50125-1 and  

IEC 61373 / DIN EN 61373 with the IP67 classification including 

vibrations/drop according to SAE J1455 (heavy trucks). 

 

 

Charging 
 

 

The battery will recharge as long as its temperature range is within 0ºC to 

+45ºC and the vehicle to which the unit is mounted is running. In case of 

temperatures outside this range the internal battery will not recharge. 

 

 

Operating 

conditions 

 

 

The internal battery will operate in temperature ranges from -20ºC to +60ºC. 

In case of temperatures outside of this range the internal battery will be 

disabled by the device. Battery lifetime is expected to be 3 years under 

normal operating conditions. 

 

 

Long term 

storage 

/operating 

conditions 

 

 
It is recommended to remove the battery during long term storage/continuous 

operation outside the temperatures specified in the operating conditions. 
 

Содержание TU501 Series

Страница 1: ...NOTE Former model ID was ME501 x 2G 3G Model ID changed in 2017 to TU501 x 2G 3G Short guide TU501 x Version 4 2 May 2019...

Страница 2: ...allation example 5 Functionality check LED on the unit 6 Installation check and update using Verify my Trackunit 7 Input filtering INFILT 8 CAN bus termination resistor 9 Troubleshooting 10 Product sp...

Страница 3: ...is located on the unit The mobile number and unit serial number are located on the box label It can be peeled off and saved for later use Do not perform installation inside a building Install the uni...

Страница 4: ...1 Digital input 3 Optional input1 Digital input 4 Can be used for INFILT function Optional input2 Digital output 1 Can be used to control a relay3 4 Additional input for TU501 2 1 Wire input M8 connec...

Страница 5: ...TU501 x Short Guide TU501 x v4 2 May 2019 Trackunit 2019 5 Installation example...

Страница 6: ...is OK and GPS has valid satellite position No light in LED No power supply Constant red light and no green light in LED Power supply is OK but NO mobile network GPS has NO satellite position Red flas...

Страница 7: ...GPS and mobile signal Mobile number Power supply voltage Internal battery voltage Status of inputs 1 4 on off Click Find again to refresh status Step 4 Basic configuration options Enter a device name...

Страница 8: ...rs To avoid this situation the digital input 4 pink wire should be connected to the chassis ground on the machine The infilt function should be activated via Verify my Trackunit Activation of input fi...

Страница 9: ...ller or if the TU501 4 is to be installed as a stub on a CAN bus with multiple CAN devices already attached The 120 ohm termination resister is a permanently installed resistor so make sure to use and...

Страница 10: ...g operating hours when machine is off Possibly due to the main breaker being on the negative wire ground wire from the machine battery When off the inputs may register a voltage level and start counti...

Страница 11: ...pply voltage 12 48 V DC Absolute maximum voltage range 8 58 V DC continuous Standby consumption GSM receiver active 10 mA 7 mA avg at 12V 24V Consumption during charging an empty battery 225 mA 115 mA...

Страница 12: ...is either machinery or battery powered Storage 40 C to 70 C Shorter battery lifetime must be expected when storage and operation occur at extreme temperatures Mechanical specifications Length 106 mm...

Страница 13: ...C rules and with RSS GEN RSS 132 RSS 133 RSS 210 and ICES 003 of the Industry Canada requirements Environmental The TU501 products comply with the environmental conditions for rolling stock and transp...

Страница 14: ...dard b Supply voltage 12V 48V Max 30A i FKS blade fuse Max 80V 3A ATO style used with Littelfuse FH2 fuse holder recommended Machinery The TU501 products comply with the essential requirements of the...

Страница 15: ...C IC Radiofrequency radiation exposure Information This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment may be installed and operated...

Страница 16: ...unit ME501 9 New model ID TU501 9 Japan ID n R 003 150064 T D150059003 This device is granted pursuant to the Japanese Radio Law This device should not be modified otherwise the granted designation nu...

Отзывы: