Machine and vehicle guidelines for correct wiring
Wire color
Description
Power
Connect to machine battery through a fuse (mandatory)
1
Ground
Connect to ground (mandatory)
Digital input 1
Can be connected to hour counter. Optional input
2
Digital input 2
Connect to the ignition signal (mandatory for vehicles and machines)
1
Digital input 3
Optional input
1
Digital input 4
Can be used for INFILT function. Optional input
2
Digital output 1
Can be used to control a relay
3/4
Additional input for TU501-2
1 – Wire input
M8 connector for access control and temperature sensor
Additional input for TU501-4
CAN High
Connect to CAN High
CAN Low
Connect to CAN Low
1 – Wire input
M8 connector for access control and temperature sensor
1: Supply voltage range 12–48V
2: Active/high when min. 9,5V DC at input
3: Max. load 200 mA