![TR-Electronic CDH582 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/tr-electronic/cdh582/cdh582_user-manual_1146691065.webp)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2020, All Rights Reserved
10/07/2020
TR-ECE-BA-GB-0163 v03
Page 65 of 91
9.1.18 TR Safety – Rotational Direction
Danger of death, severe personal injury and/or material damage due to a
jump in the absolute value when changing the counting direction function!
The internal calculation algorithm results in different absolute positions
for the counting direction settings
ascending
and
descending
. Verify
the correct function by a test run in safe mode after changing the
counting direction. Under certain circumstances, the output position
must be adjusted via the preset function.
BYTE, BOOL
Value
Description
Default
0
Measuring system – position descending clockwise
(looking at shaft, flange connection)
1
Measuring system – position ascending clockwise
(looking at shaft, flange connection)
X