(1) Press and hold the POWER ON/OFF key for one second or more to turn on the Datalogger.
The LCD turns on to indicate that the SK-L200T II or SK-L200TH IIα is in the measurement state for
temperature or temperature and humidity, respectively. Set the upper limit for the temperature first.
(2) Press the MODE key nine times.
(3) The Alarm and Hi marks light. Press the
▲
and
▼
keys at the same time
TIP:
Pressing the
▲
key and
▼
key simultaneously one more time will turn off the warning function.
(4) Use the
▲
or
▼
key to display the desired value for upper limit.
(5) Press the REC/STOP key to confirm. Next, set the lower limit for temperature.
TIP:
If the lower limit is not necessary, press the CALL/OUT key once. The SK-L200T II or SK-L200TH IIα returns to
the measurement state for temperature or temperature and humidity, respectively.
(6) The Alarm and Hi marks light. Press the
▲
and
▼
keys at the same time
NOTE:
Pressing the
▲
key and
▼
key simultaneously one more time will turn the warning function off.
(7) Use the
▲
or
▼
key to display the desired value for lower limit.
(8) Press the REC/STOP key to confirm.
TIPS:
If the lower limit is not necessary, press the CALL/OUT key once. The SK-L200T II or SK-L200TH IIα returns
to the measurement state for temperature or temperature and humidity, respectively. For setting
the humidity upper/lower limit in the SK-L200TH II α model, repeat steps (3) to (8) above.
(9) Press the CALL/OUT key once to complete the setting. The SK-L200T II or SK-L200TH IIα returns to the
measurement state for temperature or temperature and humidity, respectively.
7-5. Setting the Preset Start
Setting the Date and Time
This function is used to specify the date and time to start logging
automatically.
NOTES:
Starting this operation clears the logged data stored on the Datalogger depending on the logging
option that has been set. Always download the necessary data before setting this function.
For further information, please see the table below.