Section 1 – Introduction

 

 

Section 1. –  Introduction 

Thank you for purchasing an 

easyCHEM 770

.  

The 

easyCHEM 770 

a high quality, precision ORP and pH controller and is designed for maximum 

reliability to give you many years of reliable service. 

Despite its impressive list of features, the 

easyCHEM 770 

is a breeze to operate. This manual has 

been designed to help you get started, and also contains some handy application tips. If at any 
stage you require assistance, please contact either your local TPS representative or the TPS 
factory in Brisbane. 

Please note that the 

easyCHEM 770

 must be serviced or repaired by authorised personnel only. 

Opening the unit by unauthorised persons may cause an electrical shock, resulting in serious injury 
or death. If the power lead becomes damaged, the unit must be returned to TPS or repaired by an 
authorised person only. If in doubt, please contact TPS and we will advise you of your nearest 
authorised service centre. 

The manual is divided into the following sections: 

Section 1 – Introduction

 

The introduction includes a diagram of the 

easyCHEM 770 

unit and its connectors. Brief 

descriptions of the controls are provided. Please check the Unpacking Information section to 
ensure that you have received all accessories and any options you may have ordered. 

Section 2 – Installation

 

This section provides details on installing the 

easyCHEM 770

. It is a duplicate of the information 

found on the 

easyCHEM 770 Installation Guide

 card. 

Section 3 – Operating Instructions

 

The Operating Instructions provide details on adjusting user settings such as the Chlorine and pH 
set points, pump timer etc. The meanings of the various status and alarm messages are also 
described, along with periodic maintenance instructions. 

Section 4 – Peristaltic Dosing Pumps

 

A section devoted to the two dosing pumps fitted to the 

easyCHEM 770

. Describes usage and 

maintenance instructions. 

Section 5 – Sensor Calibration

 

Your 

easyCHEM 770

 is supplied pre-calibrated. However, calibration of the sensors should be 

checked every 3 months to maintain optimum accuracy. This section describes this procedure. 

Section 6 – User Settings

 

The factory default settings for the 

easyCHEM 770

 should suffice for most domestic pool 

installations. However, for larger domestic or commercial pools, refer to this section to customise 
the settings. 

Section 7 – Troubleshooting

 

The detailed troubleshooting section provides many useful hints and tips in case there is a problem 
with the 

easyCHEM 770

. This section will help solve most problems without the need to return the 

unit to the factory for repair. 

Section 8 – easyCHEM 770 Specifications

 

A listing of the technical specifications of the 

easyCHEM 770

Section 9 – Warranty

 

The TPS Warranty conditions are detailed in this section. Also included are details on the 
procedure to follow in case the 

easyCHEM 770 

unit needs to be returned for service or repair. 

Содержание easyCHEM 770

Страница 1: ...easyCHEM 770 Pool Management System Chlorine Acid controller with dosing pumps and timer for pool pump easyCHEM 770 User Manual Date 06 Sep 2007 Author AB Version 1 31...

Страница 2: ...td ABN 30 009 773 371 4 Jamberoo Street Springwood Brisbane Australia 4127 Phone 07 32 900 400 International 61 7 32 900 400 Fax 07 3808 4871 International 61 7 3808 4871 Email tps tps com au Web www...

Страница 3: ...h the Pool Pump OFF manually 19 3 7 Pumping to Waste 20 3 8 Backwashing the Pool Filter 21 3 9 easyCHEM 770 Display Messages 22 Section 4 Peristaltic Dosing Pumps 23 4 1 Lubricating the Pump Tubing 23...

Страница 4: ...on installing the easyCHEM 770 It is a duplicate of the information found on the easyCHEM 770 Installation Guide card Section 3 Operating Instructions The Operating Instructions provide details on ad...

Страница 5: ...Section 1 Introduction 5 1 1 easyCHEM 770 Display and Controls 1 2 easyCHEM 770 Connectors...

Страница 6: ...menus and data entry screens without saving changes Press to activate Auto Control mode The easyCHEM 770 will automatically add Chlorine and Acid as required Press to place the easyCHEM 770 into Stan...

Страница 7: ...Part No 121381 Probe Injection Tee 50mm Part No 117904 50 to 40mm reduction bushes x 2 Part No NPRB5040 Peristaltic Pump Input and Output Tube 4m x 2 Part No 116360 ZoBell ORP Solution Part A 200mL Pa...

Страница 8: ...e bottom of the chemical drums to the dosing pumps is 2 metres 4 The mains power lead from the pool pump reaches the easyCHEM 770 without straining 5 The mains power lead from the easyCHEM 770 reaches...

Страница 9: ...mm diameter vent hole to avoid suction build up IMPORTANT INFORMATION REGARDING ACID Always use dilute Hydrochloric Acid Add 5 Litres of Acid to 20 to 25 Litres of water NEVER ADD WATER TO ACID Using...

Страница 10: ...CHEM 770 controller on a sturdy wall or post using minimum 3mm or 1 8 stainless steel bolts screws or masonary anchors The easyCHEM 770 controller MUST be installed in a sheltered location Connect the...

Страница 11: ...unction has been included for those installers who wish to check the operation of the dosing pumps when installation is complete The pump priming function can also be used to prime the peristaltic pum...

Страница 12: ...reaches 700mV The control band stops the pump being rapidly switched on and off when the reading is close to the Set Point thereby increasing the pump s life 2 The exact ORP Set Point to achieve the c...

Страница 13: ...control band If the Set Point is 7 40pH the Acid pump will start when the rises above 7 60pH and stop again when the reading reaches 7 40pH The control band stops the pump being rapidly switched on a...

Страница 14: ...lorine and Acid as required Auto mode should be selected for normal operation 2 Press to place the easyCHEM 770 into Standby mode In this mode the unit will measure the ORP and pH levels of the pool b...

Страница 15: ...wer bill and for the environment by reducing the electricity being used 1 Press to display the Pump Timer menu Pool Pump Timed 2 Select Timed from the menu and press to select the default Timer progra...

Страница 16: ...is selected and press 4 The easyCHEM 770 will now prompt you to enter the Winter Start date Winter Start 15 May Enter Use the and keys to set the date and press Use the and keys to set the month and...

Страница 17: ...und if selected The Custom program is covered in section 3 4 4 To operate the pump 24 hours per day select Continuous This is covered in the next section 3 4 3 To select the Continuous program The Con...

Страница 18: ...is now displayed AM OFF 10 00 Set Enter Press or to set the hours for when the pool pump will turn OFF and press Press or to set the minutes for when the pool pump will turn OFF and press 5 The PM ON...

Страница 19: ...o be switched OFF by the Timer cycle 2 To stop the pump press select Timed or OFF and press 3 6 To Switch the Pool Pump OFF manually The pool pump can be switched OFF manually using the easyCHEM 770 a...

Страница 20: ...screen is displayed Set filter to Waste Enter The pool pump is now switched OFF Set the control on your filter to its Pump to Waste setting then press 3 The pool pump is now pumping pool water to was...

Страница 21: ...control on your filter to its Backwash setting then press 3 The pool pump will now backwash the filter to waste for 60 seconds A countdown is provided on the screen Backwashing 60 Filter 4 When the c...

Страница 22: ...ction 3 3 sOFF Emergency ShutOFF timer has been tripped See section 6 2 OFF Dosing Pump is off line due to 0 secs of ON time being set See section 6 3 2 OFF OVR for reading Dosing Pump is off line due...

Страница 23: ...acing the Pump Tubing Replace the Pump Tubing if it gets worn begins to leak or pumping volume is reduced The Pump Tubing may be replaced every year as a precautionary measure To remove the old Pump T...

Страница 24: ...ng to the compression fittings See the procedure detailed in section 2 4 The power to the easyCHEM 770 can now be re connected and switched on 4 3 PUMP Error Message The easyCHEM 770 monitors the dosi...

Страница 25: ...s select Calibrate then select Cal Temp The Temperature Calibration screen is now displayed For example 25 0o c Temp Cal 26 0o c Enter 6 Use the and keys to enter the same temperature as measured by t...

Страница 26: ...sfully performed the easyCHEM 770 will display the following message and the offset of the sensor For example Calibrate OK 0 1o c Offset 2 If a temperature calibration has failed the easyCHEM 770 will...

Страница 27: ...et and the ORP Temperature sensor into the ORP Probe socket if not already connected 4 Remove the wetting cap from the pH sensor Rinse both sensors in distilled water Shake off as much water as possib...

Страница 28: ...ymmetry or the Slope being outside these limits please consult the Troubleshooting guide section 7 4 for possible remedies 2 All calibration information is retained in memory when the easyCHEM 770 is...

Страница 29: ...d the ORP Temperature sensor into the ORP Probe socket if not already connected 4 Remove the wetting cap from the pH sensor Rinse both sensors in distilled water Shake off as much water as possible Bl...

Страница 30: ...lue For example Cal Failed Offset 70mV 3 If the reading is below 100 mV or above 400 mV the easyCHEM 770 will not even attempt calibration as this indicates a user error such as incorrect calibration...

Страница 31: ...the year then use the and keys to set the year Press the key to move to the hours then use the and keys to set the hours Press the key to move to the minutes then use the and keys to set the minutes 3...

Страница 32: ...within the limit ORP ShutOFF 70mins Enter Use the and keys to set the required time from 1 to 240 minutes Press and hold the or key to scroll rapidly 3 Press to save the ShutOFF timer setting for the...

Страница 33: ...one or more of the following Re fill the Chlorine or Acid drum if they were empty Check and re calibrate the ORP and or pH sensors to ensure the reading is actually correct Extend the ON time if the p...

Страница 34: ...psed The ON and OFF cycles for ORP and pH run sequentially This allows time for mixing for each of the chemicals and avoids the problem of the Chlorine affecting the pH reading or the Acid affecting t...

Страница 35: ...means that the easyCHEM 770 will add Chlorine when the reading gets too low Too High means that the easyCHEM 770 will reduce the ORP when it gets too high This is rare and not normally used in pool an...

Страница 36: ...ding gets too low Press or until the desired setting is selected and press 5 The current Control On Time is now displayed for example pH ON Time 1 min Enter Press or until the desired On Time is set a...

Страница 37: ...pped When the alarm function has been tripped the message Alrm flashes next to the ORP and or pH reading whichever has tripped the alarm and the easyCHEM 770 beeps Automatic control will continue even...

Страница 38: ...Section 6 User Settings 38 6 4 2 Alarm Set up Examples The following diagram illustrates the ORP alarm function of the easyCHEM 770 The Set Point is at 700 mV...

Страница 39: ...to enter the number of Litres of Chlorine that you wish to add to the pool and press The maximum dose that can be added is 25 Litres 5 The easyCHEM 770 now proceeds to add the Chlorine The display sho...

Страница 40: ...and press 4 The Reset menu is now displayed for example Calibration Full System Select Calibration and press to reset only the calibration information to factory values It will be necessary to re cali...

Страница 41: ...to reset error If error re occurs dosing pump will require service 7 3 ORP Troubleshooting Symptom Possible Causes Remedy ORP reading inaccurate 1 Platinum tip of ORP sensor dirty 2 Reference junctio...

Страница 42: ...ce if necessary Ensure that the bulb AND the reference junction are fully immersed as per diagram in section 5 2 1 Inaccurate readings even when calibration is successful Reference junction blocked Cl...

Страница 43: ...r outlet and unplug the power lead 2 Locate the fuse holder on the left hand underneath side of the unit Un screw it anti clockwise until it can be removed 3 Fully remove the glass fuse from the fuse...

Страница 44: ...Asymmetry Range 1 00 to 1 00 pH pH Slope Range 85 0 to 105 pH Buffers pH7 00 and pH4 00 Temperature Offset Range 10 0 O C to 10 0 O C Calendar Clock 24 Hour Calendar Clock Tests for valid day of the m...

Страница 45: ...ou feel that this equipment is in need of repair please re read the manual Sometimes instruments are received for repair in perfect working order This can occur where the sensor s simply requires clea...

Отзывы: