O. Accessories

Standard Accessories

Part Number

1.5 Volt Alkaline Battery (x2)

A002

Protective Boot w/ magnets

A614

Optional Accessories

Part Number

USB cradle and software

A665

Test Products International, Inc.

9615 SW Allen Blvd., Ste. 104
Beaverton, OR USA  97005
503-520-9197 • Fax: 503-520-1225
[email protected]

L270M • 1/25/05  copyright © 2005 Test Products International, Inc.

TPI 665 manual.qxd  11/14/2008  10:37 AM  Page 18

www.

.com

[email protected]

1.800.561.8187

Содержание 665

Страница 1: ...665 Differential Input Logging Manometer Instruction Manual www com information itm com 1 800 561 8187 ...

Страница 2: ...es and Benefits 5 2 Specifications 6 D CONTROLS FUNCTIONS S 7 E MAKING A MEASUREMENT 9 F SAVING DATA 10 G LOADING SAVED DATA 10 H MIN MAX 10 I PRINTING DATA 10 J CHANGING DATE TIME 11 K LOGGING DATA 12 L PC COMMUNICATION 16 M MAINTENANCE 16 N TROUBLE SHOOTING AND SERVICE 17 O ACCESSORIES 18 2 www com information itm com 1 800 561 8187 ...

Страница 3: ...Ensure connections are secure prior to applying pres sure Inspect hoses and fittings for cracks or bends prior to a pressure test Make sure the instrument battery is in good condition and there is no lo battery indication in the display Have someone check on you periodically if working alone NEVER Attempt to measure unknown high pressures C T 1 F D U M L D M A www com information itm com 1 800 561...

Страница 4: ...t Units of Seven units of measure bar kPa Measure PSI mmHg inHg mmH2O inH2O Logging Record test data with time stamp and display with optional software Data Store Save up to 16 readings MAX MIN Records Min Max readings Auto Off Conserve batteries www com information itm com 1 800 561 8187 ...

Страница 5: ...Zero Data Hold Back light Unit Selection Data Logging Auto power Off Min Max Record Resolution Selection Units of Measure 7Units bar kPa PSI mmHg inHg mmH2O inH2O Data logging 5000 Data 1sec 24 hour Data Storage 16 data points Communication IR to USB Interface and PC Application soft ware optional p n A665 Battery Type AA 1 5V 2 alkaline MN1500 LR6 Battery Life 600hour Typical Auto Power Off 20 mi...

Страница 6: ...OLS FUNCTIONS Input Connectors 1 4 NPT Keypad IR Ports for PC communica tion using optional A665 docking station IR Port for printing using optional A740 print er Display www com information itm com 1 800 561 8187 ...

Страница 7: ... SHIFT key first then this key to print readings to the optional A740 printer Press to select resolution and confirm menu selections Press the SHIFT key first then this key to turn deactivate activate auto power off Press to change the unit of measure Press the SHIFT key first then this key to zero the 665 prior to making a measurement Press to activate shift mode red key functions Press to cycle ...

Страница 8: ...ns can be used 9 ued ght g e n nt rn ro ns s ti ti E Making a Measurement Activates the display backlight Backlight powers off after 15 seconds key Press to change the unit of measure Press to activate deactivate the display hold Press to select resolution Press to cycle the bottom display through cur rent time ration in percent of reading compared to full scale and number of logged data NUM Press...

Страница 9: ... Data While EXP is displayed pressing the key will cycle the storage location up and pressing the key will cycle the storage location down This data can be printed also Please see section I H MIN MAX I Printing Data requires A740 printer The 665 will display a 10 second countdown giving you time to align the back holes approximately 4 away from the printer win dow Out will display and a 9 second c...

Страница 10: ...nth day or year 5 Once the date has been changed press 6 Press and date is displayed and date is displayed and rtc will be displayed Press 7 The lower left display indicates hours the lower right indi cates minutes and the main display indicates seconds 8 Press and to cycle through hours minutes and seconds 9 Press and to change the hours minutes and seconds 10 Exit EDIT mode by pressing www com i...

Страница 11: ...de sets up the interval or time between each logged data point The interval can be set from 1 second to 24 hours The 665 can log a total of 5000 data points NOTE The option al A665 docking station and software is required to view logged information Logging can now be started and stopped manually or set to automatically start and stop For automatic logging skip the steps below and see next page Sta...

Страница 12: ...t time for automaitc logging Logging can also be activated manually See page 12 2 Press and L St is displayed Press 3 The lower left display indicates hours the lower right indi cates minutes and the main display indicates seconds 4 Press and to cycle through hours minutes and seconds 5 Press and to change the hours minutes and seconds 6 Exit logging interval mode by pressing The logging stop time...

Страница 13: ...wer left display indicates hours the lower right indi cates minutes and the main display indicates seconds 4 Press and to cycle through hours minutes and seconds 5 Press and to change the hours minutes and seconds 6 Exit logging interval mode by pressing 7 To exit edit mode and return to normal operation press The LCD will display REC to remind you automatic logging is activated REC will blink whe...

Страница 14: ... turns off automatic logging 1 Activate EDIT mode by pressing 2 Press six times until L res is displayed 3 Press and L rES and YES is displayed 4 Press or to cycle between NO Cancel and YES Activate 6 Once YES or NO is set press 7 Exit logging interval mode by pressing edit mode to exit www com information itm com 1 800 561 8187 ...

Страница 15: ...eginning at the bot tom 2 Using a screwdriver loosen the two screws located at the bottom of the 665 3 Pull on the screws to remove the bottom cover battery holder 4 Remove the batteries and observing polarity replace them with fresh batteries 5 Re install the battery holder and tighten the screws Cleaning Use a mild detergent and slightly damp cloth to clean the surfaces of the 665 N Tr Probl Doe...

Страница 16: ...ak battery that will not turn on the low battery indicator on the LCD OFL reads in the display Indication of over pressure Remove pressure source If pressure source is removed and the 665 still displays OL the sensor is no longer working and the 665 needs service To obtain service for your 665 please return it to TPI Attn Service 9615 SW Allen Blvd Suite 104 Beaverton OR 97005 www com information ...

Страница 17: ...ssories Standard Accessories Part Number 1 5 Volt Alkaline Battery x2 A002 Protective Boot w magnets A614 Optional Accessories Part Number USB cradle and software A665 www com information itm com 1 800 561 8187 ...

Отзывы: