INSTALLATION INSTRUCTIONS
TRANSFER SWITCH WITH RECEPTACLE SECTION
CAUTION: Disconnect supply service to avoid electrical shock. All wiring connections
must conform to national electric code and local codes having jurisdiction.
1. Remove front covers from accessory and baseboard.
2. Remove knockout for supply entrance and knockout from exposed end of baseboard
for heater wire entry.
3. Attach accessory to wall with heater, insert bushing (supplied) from baseboard junction
box.
4. Make connections per wiring diagram. Connect branch circuit conductors marked “line”,
connector conductors marked “heater” to heater load conductors.
5. Attach green ground lead from accessory to heater junction box for continuity of ground.
6. Reinstall heater junction box cover and accessory cover, restore power and check for
proper operation.
FORM: 9928