INSTALLATION INSTRUCTIONS
BUILT-IN THERMOSTAT
CAUTION:
Disconnect supply service to avoid electric shock. All wiring connections must
conform to national electric code and local codes having jurisdiction.
NOTES:
*
Do not eliminate or bypass the thermal cutout.
*
Be sure load controlled by the thermostat does not exceed the thermostat nameplate
rating.
*
The in-built thermostat accessory can be mounted in either end of baseboard.
1. Remove junction box cover.
2. Remove wire nut in junction box (Do not disturb the crimp connection).
3. Install thermostat accessory in the junction box with the two (2) screws provided.
4. Make connections per wiring diagram. Connect read lead wire(s) to line supply and black
lead wire(s) to load.
5. Install one of the new junction box covers provided. Reinstall cover so the thermostat shaft
extends through cover. Press control knob on to thermostat shaft.
6. Restore power to the baseboard.
7. Thermostat operation: Turn thermostat shaft fully clockwise. When the room has reached
the desired comfort level, slowly turn thermostat shaft counter-clockwise until heater turns
off (a faint click will be heard). One or two minor adjustments may be required.
TAMPER RESISTANT THERMOSTAT INSTALLATION
1. Repeat steps 1, 2, 3, 4, 5,6 and 7.
2. Reinstall junction box cover , install plug button.
FORM: 9925
ECO 1-5177