![TPC ERN 22 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/tpc/ern-22/ern-22_user-manual_1146126065.webp)
62 / ERN C
Producer sets the value not cancel hundreths, which fits most applications.
Cancel counter accept hundreths.
Cancel counter accept hundreths.
00000.09
00000.09
MACHINE setup.
CANCEL
MACHINE setup.
CANCEL
NOT CANCEL
HUNDRETHS
NOT CANCEL
HUNDRETHS
NOT CANCEL
DEC&HUND
NOT CANCEL
DEC&HUND
CANCEL
ALL
CANCEL
ALL
9. ERROR report
Mistakes in program are displayed by writing ERROR messages:
ERROR Microswitch
Mechanical displace of the wire guide. It appears in case, that the lateral power on the wire guide
overcomes the torque of the step motor.
Next procedure: press RESET
ERROR Protection shield is open
Next procedure: press ENTER and close the shield
ERROR Spindle speed versus pitch
Pitch or spindle speed is too high (exceed the max.wire guide speed 75 mm/sek)
Next procedure: press ENTER and correct either spindle speed or pitch
ERROR Wire guide position out of range
Winding width is out of range.
Next procedure: press ENTER and correct either relative position or reversal points
ERROR Program is not logic
Program is not logic in the case type of cycle ContFAST, next step can not be the shift, jump or