The UPS is alive constantly, if the main switch (1
0
) is in off-position, as well. In common running
the UPS must be switched on constantly. In case of continual fall-out loss of the line voltage,
e.g. electric distribution breakdown, repairs and re-designs or when the running is dead, it is
necessary to set the UPS to off, that the useless discharge of storage batteries does not arise.
P
ress the button
s by instruction on label.
Repeated switch on is made by pressing the on button.
If the electric power supply was broken in the whole system - e.g. by setting the switch
EMERGENCY STOP (2) to off, by the main switch (1
0
) or the lenght of fall-out loss of the line
voltage surpassed the battery capacity of the UPS (more than 90 minutes), the hard RESET
will arise after renewing electric power supply. After pressing the ENTER button the last
remembered data from EEPROM will be set up.
If the electric power supply is broken while winding, the spindle will stop and the winding machine
switch over to the stand-by after few second. After renewing electric power supply the machine
returns to the initial regime, but in the position like after pressing the STOP button.
Keep always the following order at switching off and on the winding machine:
SWITCH ON: a) the UPS - if it was off
b) the main switch
(10)
c) the
power on
switch (1)
SWITCH OFF: a) the
power on
switch (1), wait till the
dark power on indicator
b) the main switch (1
0
)
c) the UPS only if it is necessary
4.
3
UPS
8 / ERN T / V 1.3
4.4 Machine preparation for running
The machine operating is allowed only by skilled person who is acquainted with user´s guide
and safety formulas. The training is provided by producer or qualified person.
The machine is delivered partly disassembled for easier packing and transport.
Before you switch the machine on, for the first time, assemble it as follows:
a) Mount the
display
on the drive unit. Connect the power plug
and serial interface.
b) Check and fasten the fuse cartridges on the back panel of the drive unit
c) Connect the foot pedal to the connector (
8
)
d) The UPS (
1
2) is switched on by pressing the button
Assembly is completed by this and prepared to work.
Содержание ERN 100T
Страница 8: ...5 ERN T V 1 3 UPS POWER MAN I 0 TOTAL STOP BRAKE 8 9 10 11 12...
Страница 36: ...Type of cycle 33 ERN T V 1 3 1 2 7 2 5 Delay Time of delay PROGRAM PROGRAM PROGRAM 2 1 3...
Страница 50: ...48 ERN T V 1 3 Delay 1 2...
Страница 53: ...51 ERN T V 1 3 Copy step 1 2 Pressing of button COPY STEP ends copying...
Страница 54: ...52 ERN T V 1 3 Delete step 1 2...
Страница 56: ...54 ERN T V 1 3...
Страница 58: ...56 ERN T V 1 3 9 3 Programme copy This function allows to copy programmes already created 1 2 1 2...
Страница 61: ...10 3 Model selection 10 4 Display language 59 ERN T V 1 3 Allows a selection of display language 1 2 3 1 2...