66666
Temperature parameters
Indoor setting temperature (Tpreset)
Indoor ambient temperature (Tamb.)
System basic function
Cooling mode
Dehumidifying mode
Fan mode
Heat mode
Auto mode
Other control
ON/OFF
Modes selection
Timer function
Timer on
Timer off
Manual of functions of remote controller and operation method
Manual of functions of remote controller
The system will continue to run if TIMER ON is set when the system is under ON status. If TIMER OFF is set when the system
is under OFF status, the system will start to run under preset mode upon the time for auto start.
If TIMER OFF is set when the system is under OFF status, the system will maintain its standby status upon the time for auto
stop. If the TIMER OFF is set when the system is under ON status, the system will be stopped upon the tome for auto stop.
Press the MODE button on the remote controller to select and display the following modes:
AUTO, COOL, DRY, FAN, HEAT,AUTO.
TEMP. Setting Button
3.4 Manual Button (ON/OFF )
If press AUTO button under off status of the unit, the unit will run under auto mode with swing.If press AUTO button under on
status of the unit,the unit will be stopped.If remote controller command
is given,the mian unit will run under the command.
In this mode, the system selects COOL, HEAT and FAN mode automatically according to the change of ambient temperature.
Protection function is the same as that in cooling and heating mode.
Temp. can be set in the range of 16-30 .
In heating mode, if compressor is running, indoor fan will delay to run to avoid cold air blowing.When compressor stops, blowing
When compressor stops, blowing residual heating will enter.
Blowing residual heat: In heating mode, the unit is stopped by remote controller, indoor fan will continue to run for 60s. Fan
speed can not be switched during blowing residual heat.
Indoor fan and swing will operate according to setting status.
Temp. can be set in the range of 16-30 .
Temp. can be set in the range of 16-30 .
Indoor fan will run at low speed invariably. Swing will operate according to setting status.
Temp. can be set in the range of 16-30 .
In this mode, the indoor fan will run at preset fan speed.
When the compressor stops for outdoor unit malfunction protection, the indoor fan will still run at preset fan speed.
GAN A180 IV Controller Function of Indoor Unit
Each time the On/Off
button of the remote controller is pressed, the On/Off state will switch once.
Each time
button is pressed, the set temperature will be increased or decreased by 1 .Adjusting range
is 16~30 . In AUTO mode, this button does not function.
Содержание GAN GAG A180IV
Страница 1: ...Service Manual MODEL GAN GAG A180IV GAN GAG A220IV...
Страница 6: ...Overall and Installing Dimension of Indoor Unit 18K Unit mm above above above above Bolt Nut Wrench...
Страница 7: ...Overall and Installing Dimension of Indoor Unit 24K Unit mm Bolt Nut Wrench...
Страница 8: ...Electrical Diagram GAN GAG A180IV Electrical Diagram GAN GAG A220IV...
Страница 30: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit...
Страница 32: ...Exploded View of Indoor Unit...
Страница 34: ...Exploded View of Outdoor Unit...
Страница 36: ...Exploded View of Outdoor Unit...
Страница 38: ......