3.5.3 Set TIMER ON/OFF Simultaneously
If TIMER ON and TIMER OFF is set simultaneously when the system is under run status, the system will maintain its current
status. It will be started until the time for auto start.
operating status and be stopped upon the coming of preset time
If TIMER ON and TIMER OFF is set simultaneously when the system is under stop status, the system will maintain its stop
At the time for auto start every day, the system will run under preset mode.At the time for auto stop, the system will be stopped.
Noise silencing is provided under heating mode. If the unit is restarted in less than 3 minutes after it is stopped,3-minute lag
protection is provided for the compressor.
3.5. 4 Change of Timer
When the system is under TIMER ON/OFF status, switch on or off the unit by pressing ON/OFF key by remote controller,
Timer can be reset. The system will run under the last status setting.
3.6 Sleep Function
Setting SLEEP function under COOL or DEHUMIDIFY mode, the preset temperature will automatically rise by 1
after 1
ć
hour and rise by another 1
after 2 hours. Preset temperature will rise by 2
in total within 2 hours. After that, the unit will
ć
ć
run at this preset temperature , the indoor fan will run at preset speed.
Setting SLEEP function under HEAT mode, the preset temperature will automatically decrease by 1
after 1hour and
decrease by another 1 after 2 hours. Preset temperature will decrease by 2 in total within 2 hours. After that, the
unit will run at this preset temperature , the indoor fan will run at preset speed.
No sleep function under fan mode and auto mode.
3.7 Speed Control of Indoor Fan
The indoor fan will select fan speed(HIGH, MED or LOW) automatically according to the change of ambient temp.It can also
be set by remote controller.
3.8 Buzzer
When the unitis energized, pressed, or receives a signal from remote controller, the buzzer will give out a beep.
3.9 Swing Control
After energized, guide louver will first anticlockwise turn to A position, and then close the air outlet.
After the unit is turned on, guide louver will return standby to max. air outlet D2 for heating; for cooling, guide
louver will first turn to air outlet D1 and then return standby to L1. If the unit is in swing condition, the guide
louver will swing between L1 and D1 for cooling and between L and D2 for heating.
After the unit is off, guide louver will anticlockwise turn to A position to close air outlet.
3.10 Memory Function
What can be memorized includes: mode, swing,preset temperature, preset fan speed.If the system is in timer and sleeping
.
status,preset timer and sleeping can not be memorized and will be canceled after the power is off,which must be reset,
3.11 Indoor Indicators
In normal state,power supply/mode/fan speed/preset temp. indicator will display by current state.Every time of receiving command
from remote controller,preset temp. will display blink for 10s.In other conditions,ambient temp. displays.
Содержание GAN GAG A180IV
Страница 1: ...Service Manual MODEL GAN GAG A180IV GAN GAG A220IV...
Страница 6: ...Overall and Installing Dimension of Indoor Unit 18K Unit mm above above above above Bolt Nut Wrench...
Страница 7: ...Overall and Installing Dimension of Indoor Unit 24K Unit mm Bolt Nut Wrench...
Страница 8: ...Electrical Diagram GAN GAG A180IV Electrical Diagram GAN GAG A220IV...
Страница 30: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit...
Страница 32: ...Exploded View of Indoor Unit...
Страница 34: ...Exploded View of Outdoor Unit...
Страница 36: ...Exploded View of Outdoor Unit...
Страница 38: ......