Operating Procedures / Photos
Disassemble Capillary
Unsolder the four welding points connecting the two
capillary sub-asslies with the liquid valve and the
condenser, and remove the capillary sub-assy.
As show in Fig.7-22)
Capillary
Fig.
Disassemble Gas Valve and Liquid Valve
Unscrew the four bolts fixing the two valves,
unsolder the welding point connecting the gas valve
with the return-air pipe, and remove the gas valve
(caution: when unsoldering the soldering point,
wrap the gas valve completely with wet cloth, so as
to prevent the valve body from harmed by high
temperature). Unscrew the four bolts fixging the
liquid valve, and remove the liquid valve.
(refer to Figure 7-23)
Fig.
Bolt
Bolt
Liquid Valve
Gas Valve
Disassemble Compressor
Unscrew the six nuts with washers at the feet of the
two compressors (caution: only after discharging all
freon). Unsolder the suction and the discharge pipes
of the compressor, carefully remove the pipes and
take out the compressor.
(refer to Figure 7-24)
Compressor
Fig.
Содержание GAN GAG A180IV
Страница 1: ...Service Manual MODEL GAN GAG A180IV GAN GAG A220IV...
Страница 6: ...Overall and Installing Dimension of Indoor Unit 18K Unit mm above above above above Bolt Nut Wrench...
Страница 7: ...Overall and Installing Dimension of Indoor Unit 24K Unit mm Bolt Nut Wrench...
Страница 8: ...Electrical Diagram GAN GAG A180IV Electrical Diagram GAN GAG A220IV...
Страница 30: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit...
Страница 32: ...Exploded View of Indoor Unit...
Страница 34: ...Exploded View of Outdoor Unit...
Страница 36: ...Exploded View of Outdoor Unit...
Страница 38: ......