Troubleshooting
Outdoor units
9.2.4 Protection of pressure or temp.
Protection of pressure or temp.
Is it k1 or K2 open ?
Is temp. protective switch K1
Possible reason
1. The wires is loose to K1
2. Air or other gas in the refrigerant.
3. Heat exchanger is dirty
4. Outdoor fan or fan blade is
defective
5. Outdoor unit is bad ventilation
6. Refrigerant is leakage
Is pressure protective switch K
2
Yes
Yes
Yes
Possible reason
1. The wires is loose to K
2
2. Air or other gas in the refrigerant.
3. Heat exchanger is dirty
4. Outdoor fan or fan blade is
defective
5. Outdoor unit is bad ventilation
6. Refrigerant is two much