![Toyotomi DCT 100HSPi Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/toyotomi/dct-100hspi/dct-100hspi_service-manual_1143306047.webp)
Controller
Electrical Control System
Name and function of LCD on the wire controller
1
Mode select button (MODE):
Press MODE button to select “COOL”, “DRY” , "HEAT", or "FAN ONLY" mode.(HEAT is invalid for
COOL ONLY wire controller.)
AUTO
COOL
DRY
HEAT
FAN
2
Fan speed button (FAN SPEED)
Press FAN SPEED to select fan speed from "AUTO", "LOW"," MED" , and "HIGH”. NOTE: some air
conditioners have no MED fan speed, and then the MED is regarded as HIGH.
3 Economical
operation
displays:
Press ECONOMICAL to display economical operation, if press ECONOMICAL again then the display
disappears
4 Lock
display
Press LOCK to display the icon of LOCK. Press the button again then the icon of LOCK disappears. In
the mode of LOCK, all the buttons are invalid except for LOCK button.
5 CLOCK
display.
Usually display the clock set currently. Press the button CLOCK for 4 seconds, the HOUR part will flash,
press button
Ÿ
and
ź
to adjust HOUR. Press the button CLOCK again, the minute part flash, press
button
Ÿ
or
ź
to adjust MINUTE. After clock set or clock operation, it must press CONFIRM to complete
the set.
6
TIMER ON/OFF display:
Display ON at the state of TIMER ON adjustment or after only set the TIMER ON; Display OFF at the
state of TIMER OFF adjustment or after only set the TIMER OFF; Display ON/OFF if simultaneously set
the mode of TIMER ON and TIMER OFF.
7
Temperature display area:
Usually display the set temperature. Press the buttons of and to set temperature, at the mode of FAN,
there is no figure display in the area.
Содержание DCT 100HSPi
Страница 1: ...Service Manual MODEL DCT 100HSPi o DCT 140HSPi o DCT 170HSPi o ...
Страница 6: ...Indoor units Indoor units Part 2 Indoor units High Static Pressure Type ...
Страница 9: ...Dimensions Indoor units 2 Dimensions 2 2 DCT 100HSPi 2 3 DCT 140HSPi DCT 170HSPi ...
Страница 12: ...Wiring diagrams Indoor units 5 4 DCT 100HSPi 2 3 DCT 140HSPi DCT 170HSPi ...
Страница 16: ...Static pressure Indoor units 10 Static pressure DCT 100HSPi DCT 140HSPi DCT 170HSPi ...
Страница 19: ...Dimensions Outdoor units 1 3 DCT 100HSPo 1 4 DCT 140HSPo DCT 170HSPo ...
Страница 21: ...Wiring diagrams Outdoor units 3 4 DCT 100HSPi 3 5 DCT 140HSPi DCT 170HSPi ...
Страница 33: ...Installation Installation Part 4 Installation QVWDOODWLRQ ...
Страница 41: ...Control Control Part 5 Control RQWURO ...
Страница 42: ...Control Control 1 Remote controller 7KHUH V RQH PRGHO 5 The below is R11HG E remote controller ...