P00300
Ohmmeter
Continuity
P00299
Ohmmeter
Continuity
S01424
Ohmmeter
Continuity
(A)
(B)
ST--6
--
STARTING
STARTER
Standard undercut depth:
1.0kW, 1.2 kW, 1.4kW type:
0.6 mm (0.024 in.)
2.0 kW type:
0.7 mm (0.028 in.)
Minimum undercut depth:
0.2 mm (0.008 in.)
If the undercut depth is less than the minimum, correct it with
a hacksaw blade.
7.
INSPECT FIELD COIL FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
lead wire and field coil brush lead.
If there is no continuity, replace the field frame.
8.
INSPECT FIELD COIL FOR GROUND
Using an ohmmeter, check that there is no continuity between
the field coil end and field frame.
If there is continuity, repair or replace the field frame.
9.
2.0 kW type:
INSPECT SHUNT COIL FOR RESISTANCE
Using an ohmmeter, check that the resistance between the
shunt terminal (A) and shunt terminal (B).
Standard Resistance: At 20
˚
C (68
˚F)
: 1.5 -- 1.9
Ω
CLICK HERE TO VIEW CHAPTER INDEX
Pages From Supplement
3RZ-F,3RZ-FE