name. SIENNA (45403U)
255
Battery recharging precautions
During recharging, the battery is pro-
ducing hydrogen gas.
Therefore, before recharging:
1. If recharging with the battery installed
on the vehicle, be sure to disconnect
the ground cable.
2. Be sure the power switch on the re-
charger is off when connecting the
charger cables to the battery and when
disconnecting them.
CAUTION
D
Always charge the battery in an un-
confined area. Do not charge the
battery in a garage or closed room
where there is not sufficient ventila-
tion.
D
Only do a slow charge (5 A or
less). Charging at a quicker rate is
dangerous. The battery may ex-
plode, causing personal injuries.
NOTICE
Never recharge the battery while the
engine is running. Also, be sure all
accessories are turned off.
Checking and replacing fuses
Good
Type A
Type B
Type C
Good
Good
Blown
Blown
Blown
If the headlights or other electrical
components do not work, check the
fuses. If any of the fuses are blown,
they must be replaced.
See ”Fuse locations” in Chapter 7
−
1 for
locations of the fuses.
Turn the ignition switch and inoperative
component off. Pull a suspected fuse
straight out and check it.
Determine which fuse may be causing the
problem. The lid of the fuse box shows
the name of the circuit for each fuse. See
Part 8 of this manual for the functions
controlled by each circuit.
Содержание 1999 Sienna
Страница 8: ...name SIENNA 45403U 8...
Страница 102: ...name SIENNA 45403U 102...
Страница 114: ...name SIENNA 45403U 114...
Страница 180: ...name SIENNA 45403U 180...
Страница 194: ...name SIENNA 45403U 194...
Страница 206: ...name SIENNA 45403U 206...
Страница 224: ...name SIENNA 45403U 224...
Страница 230: ...name SIENNA 45403U 230...
Страница 236: ...name SIENNA 45403U 236...
Страница 239: ...name SIENNA 45403U 239 Fuse locations Spare fuses Without daytime running light system With daytime running light system...
Страница 252: ...name SIENNA 45403U 252...
Страница 262: ...name SIENNA 45403U 262...
Страница 270: ...name SIENNA 45403U 270...