Dampers left open 

Operation with the air controls or appliance dampers open can cause excess smoke. The 
appliance must not be operated with air controls, appliance dampers or door left open 
except as directed in the instructions. 

 

FUELS 

 

This appliance has been tested using seasoned wood logs and manufactured briquetted 
smokeless fuel (Ancit) for closed appliances, sized between 20g and 140g. Other fuels are 
commercially available and may give similar results.    Do not use household coal. It is a 
good idea to try small quantities of different fuels until you find one that suits your 
chimney.    Petrocoke or any petroleum based fuel such as Cozycoke, Excell & Burnwell     
must 

NOT 

be used, they burn excessively hot and will destroy parts of the stove in a very 

short time. If using logs, the logs need to be dry, seasoned logs, ie. No more than 20% 
moisture content, maximum log length up to 400 mm x 100 mm diameter. Small pieces of 
kiln dried timber can burn very hot, take care that the fire does not get out of control. The 
stove is designed to burn wood or solid fuel. 
 

WARNING – USING A NON APPROVED FUEL MAY CAUSE DAMAGE TO THE 
STOVE AND WILL NOT BE COVERED BY OUR GUARANTEE. WOOD NEEDS TO 
BE DRY AND SEASONED (MAXIMUM 20% MOISTURE CONTENT)   
DO NOT BURN ANY LIQUID FUEL. DO NOT BURN WOOD PELLETS.DO NOT 
BURN WOOD CHIPS. DO NOT BURN ANY RUBBISH ON THE STOVE. DO NOT 
USE HOUSEHOLD COAL, HIGH PETROLEUM BASED FUELS, PETROCOKE, 
COSY COKE, EXCEL, PUREHEAT, NEWHEAT, BURNWELL OR ANTHRACITE. (A 
COMPREHENSIVE LIST OF APPROVED FUELS FOR CLOSED APPLIANCES IS 
AVAILABLE ON THE HETAS WEBSITE)   

 
Suitable manufactured smokeless fuels approved by Hetas for use in closed stoves include   
Homefire Ovals, Phurnacite, Taybrite, Multiheat,Ancit, Briteheat and Ecoal 50. 
 

TO OPERATE THE REMOTE CONTROL OPTION –    IF FITTED 

 

If the Remote Control option is installed on your stove – the remote controls the 
secondry air intake on the Langdale Smoke Control and is operated by 4 x AA 
batteries in the control box and a 9V battery in the handset (batteries included). 
No mains electrity supply is required.    To operate the remote control, the air 
lever at the front of the stove must be in the open position (slide the lever to the 
left).   
 
Press and hold down the small button on the left of the hand set together with 
the button next to the up arrow – this will open the air intake at the rear of the 
stove. To close the air intake press the bottom button next to the down arrow. 

Содержание LANGDALE SMOKE CONTROL

Страница 1: ...ide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system WARNING T...

Страница 2: ... from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorize smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with the Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern ...

Страница 3: ...ke Control a minimum of 200mm at the back and 400mm at the sides must be maintained from combustible surfaces It is a requirement that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations This appliance has been tested for hearth temperatures and the maximum temperature was 81 degrees C so is also suitable for a 12mm hearth INSTALLATION A m...

Страница 4: ...s required preferably made of metal Acollar is welded to the underside of the register plate so that the flue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of seeping out onto the top of the stove Connect the st...

Страница 5: ...touch or wipe the paint during this period as it will be soft and may mark The room should be well ventilated children and pets should be kept away Do not use water to clean the stove either before or after it is cured TURBO BURNER There is a Turbo Burner which brings air in allowing plenty of oxygen into the rear and top of the stove thus burning off gases which normally do not ignite This gives ...

Страница 6: ...d The door should be kept closed at all times except when refueling or removing ashes The appliance is designed to operate efficiently with the fire door closed door The door should be kept closed at all times except when refueling or removing ashes Operation with the stove door open can cause excessive smoke The appliance must not be operated with the stove door left open TO RE FUEL THE STOVE Do ...

Страница 7: ...VED FUEL MAY CAUSE DAMAGE TO THE STOVE AND WILL NOT BE COVERED BY OUR GUARANTEE WOOD NEEDS TO BE DRY AND SEASONED MAXIMUM 20 MOISTURE CONTENT DO NOT BURN ANY LIQUID FUEL DO NOT BURN WOOD PELLETS DO NOT BURN WOOD CHIPS DO NOT BURN ANY RUBBISH ON THE STOVE DO NOT USE HOUSEHOLD COAL HIGH PETROLEUM BASED FUELS PETROCOKE COSY COKE EXCEL PUREHEAT NEWHEAT BURNWELL OR ANTHRACITE A COMPREHENSIVE LIST OF AP...

Страница 8: ...y used in the factory can be obtained from you supplier Warning do not use an aerosol spray near the stove when the stove is alight This appliance should be regularly maintained by a competent service engineer There must be no unauthorised modification of the appliance Any replacement parts must be recommended by the Manufacturer and can be purchased from the approved dealer the stove was original...

Страница 9: ...himney Check that the fuel being used is as described and that the operation of this manual is being followed If smoke is being emitted whilst refueling onto a low firebed then kindling should be used IN CASE OF A CHIMNEY FIRE CLOSE ALLAIR VENTS IF POSSIBLE MAKE SURE THERE IS NOTHING COMBUSTIBLE NEAR THE STOVE MOVE PEOPLE AWAY FROM THE ROOM CLOSE THE ROOM DOOR PHONE THE FIRE BRIGADE WARNING NOTE P...

Страница 10: ...n completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance and operating tools and warn them to use only the recommended fuel for the stoves Advise the user what to do should smoke of fumes be emitted from the stove The customer should be warned to use a firegua...

Страница 11: ...r our Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Paint Claims under this g...

Отзывы: