This fi replace may be recessed up to a
maximum depth of 6”, this recess must
be constructed from non combustible
material. The space between the outside
lintels and the fi rebox must be complete-
ly free of any obstructions or debris and
the window with trim fi tted must be able
to move freely. No building material is
permitted to protrude past the lintel bars
attached to the fi replace under ANY cir-
cumstance.
Fig. #19
FRAMING
EDGES
GLASS
FRAME
NON COMBUSTIBLE
FINISH MATERIAL
2. Attach the Assembled Frame to the
Unit
•
Align the assembled frame to the unit
framing brackets. (Fig #17) Attach at
the fastening points through the access
holes in the outer side studs (3).
3. Secure to Existing Framing
•
Bend out the tabs 90 degrees before
inserting the unit into its framed housing
(Fig. #18).
•
Secure the frame assembly to the wood
frame through the tabs.
4. Install Non-Combustible Board
(not supplied)
Fig. #17
Fig. #18