12
”
9 5/8”
12
”
74 1/4"
55 1/4"
74 1/4"
22 1/16"
11 5/16"
5/8"
80 5/8"
46 1/4"
33"
114"
74 1/4"
INCLUDING SHEETROCK
MAXIMUM FACING DEPTH
IF FINISHING THE WALL ABOVE THE
UNIT WITH PAINT, THE FRAMING
KIT SHIPPED WITH THE UNIT
SHOULD BE DISCARDED.
IT IS RECOMMENDED TO USE FULL
SHEETS OF CALCIUM SILICATE
BOARD OR ITS EQUIVALENT AND
FULL LENGTH METAL STUDS TO
FINISH AND FRAME AROUND THE
UNIT.
FOLLOW THE
MANUFACTURERS
MOUNTING AND FINISHING IN-
STRUCTIONS CLOSELY.
NOTE:
IT IS RECOMENDED TO PRE-
DRIL MOUNTING HOLES IN THE
BOARD PRIOP TO SECURING TO
THE FRAMING. THIS WILL PREVENT
THE BOARD FROM CRAKING.
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE RECESSED
INSTALLATION DETAIL
NON-COMBUSTIBLE BOARD DETAIL
MINIMUM COMBUSTIBLE
FRAMING DIMENSIONS
Fig. #13a
Fig. #13
Fig. #14
Fig. #15
NON-COMBUSTIBLE
MATERIAL MUST EXTEND
12" ABOVE, 9 5/8" TO THE
SIDES AND 12” BELOW THE
FRAMING EDGES.
NON-COMBUSTIBLE
BOARD
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING.
STEEL STUDS
NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
NON-COMBUSTIBLE
BOARD
11
TCWS.54CODE 102813-40
Содержание TCWS.54OD
Страница 30: ...Fig 43 Wiring Diagram 30 TCWS 54CODE 102813 40 ...
Страница 35: ...35 TCWS 54CODE 102813 40 ...
Страница 36: ...36 TCWS 54CODE 102813 40 ...
Страница 37: ...37 TCWS 54CODE 102813 40 ...
Страница 38: ...38 TCWS 54CODE 102813 40 ...