Before installing venting for this unit, the installer should read these instructions to insure
that the proper vent confi guration has been selected.
Use only Town and Country Termination kits #:
TCVT.RTA - Roof Termination Kit
Vent system components approved for use with the Town and Country Fireplace are shown
in Fig. #34.
Various combinations of vent runs may be used. Refer to Fig. #28 for details. For optimum
performance and fl ame appearance, keep the vent length to a minimum and limit the number
of elbows. Connections between each vent system component must be tightly joined, secured
with sheet metal screws and sealed with high temperature self adhesive tape.
VENT SUPPORTS:
A minimum of 1 support every 4’ must be used.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER
THAN 1 3/4 INCHES FROM ANY PART OF THE VENT PIPE.
18
TCWS.54CODE 102813-40
Venting