This power vent system can only run on
115 V AC. Before operating the unit, the
battery backup located behind the wall
switch receiver must be removed.
8
TCVT.WSPVB1
091009-12
5) Connect the pressure switch pig tails to
the orange wire. (Fig. # 14 & 15)
6) Attach the silicone tube from the vent
adapter pressure tapping to the low side
of the switch. (Fig. # 14 & 15)
Caution: Connect the switch prior to
securing. In the case of accidentally
dropping the switch between the control
box and firebox it can still be easily
retrieved with the wires.
7) Secure the pressure switch to the control
box using the 2 screws provided with this
kit. (Fig. # 15A)
WARNING: This switch must be installed
in a vertical position and will not function
if installed otherwise. (Fig. 15B)
Fig. # 14
PRESSURE
SWITCH
ORANGE WIRE
Fig. #15
Fig. #15A
LOW SIDE
OF SWITCH
Fig. #15B
8) Continue with installation and reassemble
all of the parts previously removed.
WARNING: Both the control box shield
and access panel must be reinstalled
after conversion\ installation or servicing
has been completed. Failure to do so will
overheat and cause premature failure of
the control system.