VENTING CONFIGURATIONS
Maximum vent length is 110 ft
plus six 90-degree elbows or
combination of other elbows
equaling 90-degrees, with a
maximum 66 foot vertical rise.
Minimum vent length is 4 ft
plus one 90-degree elbow.
The vent can be installed
with any combination of rise
and run between the figures
including up to 3 ft below
the unit. Ensure vent pipe is
properly supported.
Maximum combined
vertical & horizontal
venting -
110 ft plus six
90-degree elbows.
Vertical Application must use TCVT.PVVCA Box in
conjunction with this kit
4 ft min.
6 ft min.
Maximum
vertical of 66 ft
Min. venting - 4 ft plus
one 90-degree elbow
3 ft below unit (Max) to
centerline of vent pipe
Fig. #1
Max Pipe
Length
2
TCVT.WSPVB1
091009-12
Contents of Power Vent Kit
Power Vent Installation
Locate the fireplace as per the main instructions supplied.
Make the following modifications to add the components used with the Power Vent Kits. This Kit can only be used in
conjunction with the Town and Country WS fireplaces. This installation must conform with local codes or, in the absence
of local codes, with the Natural Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code,
CSA B149.1. This appliance must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.
MINIMUM CLEARANCES TO
COMBUSTIBLE
Vertical vent pipe:
1.5 in. (38mm)
Horizontal vent pipe:
Top
1.5 in. (38mm)
Sides
1.5 in. (38mm)
Bottom
1.5 in. (38mm)
All other clearances are as
per the fireplace installation
instructions.
Fig. #1a
WALL TERMINATION VENTING CHART
49” 0” 110 feet
4 feet
57” 12” 109 feet
3 feet
65” 24” 108 feet
2 foot
Min Pipe
Length
A B C
Pipe
Length
Min.
Rise
ITEM
PART No.
DESCRIPTION
QTY. ITEM
PART No.
DESCRIPTION
QTY.
1
TCVT.502461
Power Vent Terminal
1
5
5027.15
Pressure Switch
1
2
5096.814
Venting Adaptor
1
6
8240
Tubing, TYSC-516316-100
1
3
TCVT.50271C2
Pressure Switch Wiring
1
7
Hose Clamp
1
4
8271
Pressure Switch Bracket
1
8
5093.02
Hose Clamp
1
9
TCVT.507156C
PV Module Switch Wire
1