WARNING
This conversion kit
shall be installed by a
qualifi ed service agency
in accordance with the
manufacturer's instructions
and all applicable codes and
requirements of the authority
having jurisdiction.
If the information in these
instructions is not followed
exactly, a fi re, explosion
or production of carbon
monoxide may result
causing property damage,
personal injury or loss of
life.
The qualifi ed service agency
is responsible for the proper
installation of this kit. The
installation is not proper and
complete until the operation
of the converted appliance is
checked as specifi ed in the
manufacturer's instructions
supplied with the kit
.
If the unit is to be used on propane,
convert as follows using the
components supplied with this
fi replace:
CAUTION
The gas supply and electrical power
must be shut off before proceeding
with the conversion.
Note:
Factory supplied components must be used
to ensure correct input. After conversion
confi rm proper manifold pressure.
1. Ensure the burner, pilot and gas
supply are turned off, and the
appliance has cooled.
2. Using a 1/2” wrench, undo both natural
gas burner orifi ces (marked
#29
).
(Fig.
#18)
3. Apply a small amount of pipe joint com-
pound to the threads of the propane
burner orifi ce (marked #
44
) to ensure
a good seal, before screwing it into the
fi tting.
4. Open primary air shutters fully.
5. With a 7/16” wrench loosen the pilot head
on the pilot assembly (Fig. #19)
6. Slide the pilot adjustment band over and
ensure that the hole in the orifi ce band is
showing. (Fig. #20 indicates NG position,
Fig. #21 indicates LP position)
Repeat steps 5 and 6 for other pilot.
TC54.NGO3C2 070211-16
Fig #18
Fig #19
Fig #20
Fig #21
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
11.0 in/wc / 11.0 po/c.e.
(.95 kPa)
#44 (2.18 mm)
Max.: 83,700 (24.53)
Min.: 67,000 (19.63)
230910 6-TC54C2 5052.520862
Date: ______________________
By / Par: ___________________
Kit# TC54.LPCE02 for use with model /
Pour utilise avec du modèle:
TC54.CE2
This appliance was con-
verted to PROPANE GAS
with this kit on this date
by the organization which
accepts the responsibility
that this conversion has
been properly made. / Cet
appariel etair converter au
gaz LP par l’emploi de la
trousse de conversion par
une organization qui ac-
cepte la responsibilité pour
une installation en bon état.
MAIN BURNER
(#44) ORIFICES (5022.92)
MINIMUM RATE SCREW (5005.015)
CONVERSION LABEL (5052.52086)