1.
Remove the plug from the pressure test
port using a 7/16” socket and extension.
The plug is located between the right
side lintel and fi rebox side.
(Fig.
#27)
2.
Thread the extension test fi tting into the
open test port. (Fig. #28)
3.
Attach a pressure gauge onto the
fi tting.
4.
When testing is complete remove the
extension test fi tting and replace the plug.
Thread sealant will be required to ensure
a gas tight connection.
Note: To test the gas pressure, turn off the gas supply before removing the plug from
the supply pressure test port or manifold pressure test port.
Verify gas pressures with the fi replace lit and on the highest setting.
Correct gas pressure requirement:
Supply Pressure
Natural Gas
Propane
Min. Pressure
5.0" WC
12.5" WC
(For purpose of input adjustment)
Max. Pressure
13.9" WC
13.9" WC
Manifold
Pressure
Maximum
3.4" WC
11" WC
Minimum
1.8" WC
5.5" WC
TC54.NGO3C2 070211-16
Fig #27
Fig #28
SUPPLY
PRESSURE
MANIFOLD
PRESSURE
Fig #26a
10
Gas Pressure Check
Содержание TC54.NG03C2