WARNING
This conversion kit
shall be installed by a
qualified service agency
in accordance with the
manufacturer's instructions
and all applicable codes
and requirements of
the authority having
jurisdiction.
If the information in these
instructions is not followed
exactly, a fire, explosion
or production of carbon
monoxide may result
causing property damage,
personal injury or loss of
life.
The qualified service
agency is responsible for
the proper installation of
this kit.
The installation is not
proper and complete
until the operation of the
converted appliance is
checked as specified in the
manufacturer's instructions
supplied with the kit.
If the unit is to be used on propane
convert as follows using the
components supplied with this
burner:
CAUTION
The gas supply and electrical power
shall be shut off before proceeding
with the conversion.
Note: Factory supplied components must be
used to ensure correct input.
After conversion confirm proper manifold
pressure.
1. Remove the 2 front screws holding the
burner tray in place.
(Fig. #16)
2. Gently lift up the burner tray while
sliding to the left to disengage the
burner tube from the orifice. Then tip
back to expose the orifice.
3. Using a 1/2” wrench, undo the
natu ral gas burner orifice,
(marked
#25). Apply a small amount
of pipe joint compound to the threads
of the propane burner orifice
(marked
2.50) to ensure a good seal,
before screwing it into the fitting.
Loosen the primary air shutter screw,
open shutter fully and re-tighten.
(Fig. #17)
4.
Remove the 2 screws
holding the pilot assembly in place with
a stubby screwdriver.
(Fig #18)
The burner assembly must
be removed from the unit if
previously installed.
Propane Conversion
Fig #16
Fig #17
Fig #18
MAIN BURNER ORIFICE (2.50 mm)
(P/N # 5022.3)
CONVERSION LABEL (5052.5206 D)
Date:
______________________
By / Par:
___________________
LP GAS/
DU GAZ LP
12.5 in/wc /12.5 po/c.e.
(3.11 kPa)
13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
10.0 in/wc / 10.0 po/c.e.
(2.49 kPa)
2.50 mm
Max.: 61,000Btu (17.8kw)
Min.: 47,000Btu (13.7kw)
081014 6-TC36ST_D 5052.5206D
This kit for use with model: / TC36STNG03.D
Pour utilise avec du modèle: / TC36STNG04.D
TC42
Series D
This appliance was converted
t o P R O PA N E G A S w i t h
this kit on this date by the
organization which accepts
the responsibility that this
conversion has been properly
made. / Cet appariel etair
converter au gaz LP par l’emploi
de la trousse de conversion par
une organization qui accepte
la responsibilité pour une
installation en bon état.
9
TC36ST_NGST04D_
091014-16
Fig #15
Содержание TC36ST.NGST04D
Страница 14: ...TC36ST_NGST04D_091014 16 14 ...