11
TC36ST_NGST04D_
091014-16
Note: To test the gas pressure, turn off the gas supply
before removing the plug from the pressure test port.
Verify gas pressures with the fireplace lit and on the
highest setting.
1.
Remove the plug from the pressure test port us-
ing a 7/16” socket and extension. The plug is located
between the right side lintel and firebox side. (Fig. #21)
CORRECT GAS PRESSURE REQUIREMENT:
Supply Pressure
Natural Gas
Propane
(For purpose of input adjustment)
Minimum
5.0” wc
12.5” wc
Maximum
13.9” wc
13.9” wc
Manifold pressure
Maximum
3.5” wc
10.0” wc
Minimum
1.6” wc
6.4” wc
2.
Thread the extension test fitting into the open port.
(Fig. #22)
3.
Attach a pressure gauge onto the fitting.
4.
When testing is complete shut off the gas, remove the
fitting and replace the plug. Thread sealant will be required
to ensure a gas tight connection.